Multiobjective Optimization of Layout and Characteristics of Bidirectional Converter in Metro Traction Substation
IEEE Transactions on Transportation Electrification · 2026-06 · 12 (3) · 4360-4374
DOI: 10.1109/tte.2026.3670267 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Transportation Electrification, 2026-06. Verfasst von Chengcheng Fu und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Enhancing the stability and energy efficiency of metro power-supply systems through advanced traction technologies and upgraded infrastructure represents a critical pathway toward sustainable urban rail transit. Current systems face challenges of catenary voltage fluctuation, which compromise operational safety and stability, alongside high energy consumption that undermines economic performance. Bidirectional converter (BC)-equipped traction substations (TSs) offer a promising solution by stabilizing grid voltage and recovering regenerative braking energy, yet their efficacy hinges on optimal deployment and tuning. This study presents an integrated optimization framework for the siting and droop characteristics of BCs retrofitted from existing rectifier substations. A dynamic power-flow computation platform is developed to simulate multitrain operations under heterogeneous traction power-supply conditions, enabling the accurate calculation of system-level electrical behavior. Based on this, a multiobjective optimization model is formulated to minimize the number of BC deployments, the maximum contact line voltage deviation, and the total energy consumption. An enhanced multiobjective whale optimization algorithm incorporating an adaptive elite evolutionary strategy is proposed to efficiently solve the resulting high-dimensional, nonconvex problem. Based on the data of Wuxi Metro Line 1, numerical experiments demonstrate that the optimized BC configuration (deploying eight BCs) reduces peak voltage fluctuation by 33.9% and system-wide energy consumption by 11.5%, while yielding a 7.4% reduction in overall costs considering investment expenses. The proposed methodology provides a systematic and economically viable approach to significantly enhancing the safety and energy efficiency of metro powertrain integrated systems.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Fu, C., Luo, C., Li, Y., Sun, P., Wang, Q., & Feng, X. (2026). Multiobjective Optimization of Layout and Characteristics of Bidirectional Converter in Metro Traction Substation. IEEE Transactions on Transportation Electrification, 12(3), 4360-4374. https://doi.org/10.1109/tte.2026.3670267
Vancouver
Fu C, Luo C, Li Y, Sun P, Wang Q, Feng X. Multiobjective Optimization of Layout and Characteristics of Bidirectional Converter in Metro Traction Substation. IEEE Transactions on Transportation Electrification. 2026;12(3):4360-4374. doi:10.1109/tte.2026.3670267
BibTeX
@article{Fu2026,
author = {Fu, Chengcheng and Luo, Can and Li, Yunjia and Sun, Pengfei and Wang, Qingyuan and Feng, Xiaoyun},
title = {Multiobjective Optimization of Layout and Characteristics of Bidirectional Converter in Metro Traction Substation},
journal = {IEEE Transactions on Transportation Electrification},
year = {2026},
volume = {12},
number = {3},
pages = {4360--4374},
doi = {10.1109/tte.2026.3670267}
}