EUVIMEDEUVIMED entdecken
Crossref

Multiphysics Modeling, Analysis, and Validation of Immersion-Cooled Five-Level ANPC Inverters for Electric Propulsion

Reza Ilka, Benjamin Luckett, Majid T. Fard, JiangBiao He

IEEE Transactions on Transportation Electrification · 2026-06 · 12 (3) · 4925-4936

DOI: 10.1109/tte.2026.3665703 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Transportation Electrification, 2026-06. Verfasst von Reza Ilka und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Part of the effort for the research of this article was sponsored by Valvoline Global Operations.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the emerging transportation electrification applications, there is an increasing demand for concurrently pursuing high reliability, high energy efficiency, and high power density of power converters. Conventional cooling technologies, such as using bulky heatsinks or cold plates, have constrained further performance improvements of power converters. Based on an innovative immersion cooling technique, this article presents a high-fidelity multiphysics modeling and experimental validation framework for a 100-kW five-level active neutral point clamped (5L-ANPC) power inverter, making it the first comprehensive study on this topic. The study begins by examining the electrical performance of the 5L-ANPC inverter, followed by the computation of semiconductor losses to be used as heat sources in subsequent thermal simulations. Afterward, the immersion-cooled inverter is modeled and analyzed by conducting high-fidelity computational fluid dynamics (CFD) simulations. Various operating conditions and thermal design factors for the immersion-cooled 5L-ANPC inverter are considered, and the related impacts are investigated to characterize the thermal performance of the inverter. The results demonstrate significantly reduced semiconductor junction temperatures and more uniform heat distribution compared to conventional air cooling. The findings highlight the advantages of immersion cooling in thermal management, leading to higher output power and higher reliability. Finally, prototypes of air- and immersion-cooled inverters are developed with intensive testing to compare the thermal performance. The multiphysics simulation results showing the superior performance of immersion cooling are also verified in the experiments.

Förderung

  • Part of the effort for the research of this article was sponsored by Valvoline Global Operations

Zitieren

APA

Ilka, R., Luckett, B., Fard, M. T., & He, J. (2026). Multiphysics Modeling, Analysis, and Validation of Immersion-Cooled Five-Level ANPC Inverters for Electric Propulsion. IEEE Transactions on Transportation Electrification, 12(3), 4925-4936. https://doi.org/10.1109/tte.2026.3665703

Vancouver

Ilka R, Luckett B, Fard MT, He J. Multiphysics Modeling, Analysis, and Validation of Immersion-Cooled Five-Level ANPC Inverters for Electric Propulsion. IEEE Transactions on Transportation Electrification. 2026;12(3):4925-4936. doi:10.1109/tte.2026.3665703

BibTeX
@article{Ilka2026,
  author = {Ilka, Reza and Luckett, Benjamin and Fard, Majid T. and He, JiangBiao},
  title = {Multiphysics Modeling, Analysis, and Validation of Immersion-Cooled Five-Level ANPC Inverters for Electric Propulsion},
  journal = {IEEE Transactions on Transportation Electrification},
  year = {2026},
  volume = {12},
  number = {3},
  pages = {4925--4936},
  doi = {10.1109/tte.2026.3665703}
}
Kostenlos starten →