Uniform Demagnetization Fault Diagnosis of PMSM Based on Radial Air-Gap Flux Density Under Nonstationary Conditions
IEEE Transactions on Transportation Electrification · 2025-04 · 11 (2) · 6690-6699
DOI: 10.1109/tte.2024.3515114 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Transportation Electrification, 2025-04. Verfasst von Shichuan Ding und 2 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Outstanding Youth Research Project in University of Anhui Province, University Synergy Innovation Program of Anhui Province.
Abstract (Originalsprache)
Permanent magnet synchronous motor (PMSM) often operates in harsh environments, such as high temperatures and intense vibrations, which could result in partial demagnetization fault or uniform demagnetization fault (UDF). Although the probability of UDF is relatively low, once it occurs, it will cause a decrease in motor efficiency and even system paralysis. In addition, the PMSM usually operates under nonstationary conditions, which could increase the difficulty in UDF diagnosis. Hence, this article proposes a UDF diagnosis method of PMSM based on radial air-gap flux density under nonstationary conditions. In this method, the d-axis magnetic network model of PMSM is established and analyzed. The fault feature for UDF is extracted from radial air-gap flux density based on the d-axis magnetic network model. By the extracted fault feature, not only UDF can be detected, but also UDF degree can be calculated. Both the simulation and experimental results validate the effectiveness of the proposed UDF diagnosis method.
Förderung
- National Natural Science Foundation of China
- Outstanding Youth Research Project in University of Anhui Province
- University Synergy Innovation Program of Anhui Province
- Anhui Provincial Major Science and Technology Project
Zitieren
APA
Ding, S., He, W., & Hang, J. (2025). Uniform Demagnetization Fault Diagnosis of PMSM Based on Radial Air-Gap Flux Density Under Nonstationary Conditions. IEEE Transactions on Transportation Electrification, 11(2), 6690-6699. https://doi.org/10.1109/tte.2024.3515114
Vancouver
Ding S, He W, Hang J. Uniform Demagnetization Fault Diagnosis of PMSM Based on Radial Air-Gap Flux Density Under Nonstationary Conditions. IEEE Transactions on Transportation Electrification. 2025;11(2):6690-6699. doi:10.1109/tte.2024.3515114
BibTeX
@article{Ding2025,
author = {Ding, Shichuan and He, Wang and Hang, Jun},
title = {Uniform Demagnetization Fault Diagnosis of PMSM Based on Radial Air-Gap Flux Density Under Nonstationary Conditions},
journal = {IEEE Transactions on Transportation Electrification},
year = {2025},
volume = {11},
number = {2},
pages = {6690--6699},
doi = {10.1109/tte.2024.3515114}
}
EUVIMED