Quantitative Diagnosis of Micro-Short-Circuit Fault for Lithium-Ion Batteries Based on Correlation-Reconstructed Voltages
IEEE Transactions on Transportation Electrification · 2025-02 · 11 (1) · 2356-2367
DOI: 10.1109/tte.2024.3421557 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Transportation Electrification, 2025-02. Verfasst von Haitao Yuan und 4 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Special Funds of the Central Government Guiding Local Science and Technology Development.
Abstract (Originalsprache)
Short circuit (SC) is an important cause of thermal runaway in electric vehicles (EVs) batteries. A battery model is a valuable tool for quantitatively diagnosing micro-SC (MSC) faults to monitor and reduce the risk of thermal runaway. However, it poses a considerable challenge, as the accuracy of the model is influenced by the MSC current. This article proposes a correlation voltage feedback strategy (CVFS) for online quantitative diagnosis of MSC fault within the serial battery module, which avoids the interference of the MSC on the model accuracy and has good robustness to the state of charge (SOC) inconsistency. In particular, the CVFS reconstructs cell voltages based on the voltage correlation among different battery cells. The faulty cell with MSC is detected and located by evaluating the residual between the measured voltage and the reconstructed voltage. In addition, cell parameters are identified with the feedback of the reconstructed voltages to eliminate the effects of MSC on battery model. To improve the computational efficiency, the SC resistance is estimated only using the data from the faulty battery in combination with the unscented Kalman filter (UKF). The effectiveness of the proposed method is validated using serial batteries with a wide-range SC resistance of 10– $200~\Omega $ and SOC inconsistency, and the results demonstrate the accurate quantitative diagnosis of MSC faults with an estimated error lower than 3.31%.
Förderung
- National Natural Science Foundation of China
- Special Funds of the Central Government Guiding Local Science and Technology Development
Zitieren
APA
Yuan, H., Li, C., Cui, Z., Shang, Y., & Cui, N. (2025). Quantitative Diagnosis of Micro-Short-Circuit Fault for Lithium-Ion Batteries Based on Correlation-Reconstructed Voltages. IEEE Transactions on Transportation Electrification, 11(1), 2356-2367. https://doi.org/10.1109/tte.2024.3421557
Vancouver
Yuan H, Li C, Cui Z, Shang Y, Cui N. Quantitative Diagnosis of Micro-Short-Circuit Fault for Lithium-Ion Batteries Based on Correlation-Reconstructed Voltages. IEEE Transactions on Transportation Electrification. 2025;11(1):2356-2367. doi:10.1109/tte.2024.3421557
BibTeX
@article{Yuan2025,
author = {Yuan, Haitao and Li, Changlong and Cui, Zhongrui and Shang, Yunlong and Cui, Naxin},
title = {Quantitative Diagnosis of Micro-Short-Circuit Fault for Lithium-Ion Batteries Based on Correlation-Reconstructed Voltages},
journal = {IEEE Transactions on Transportation Electrification},
year = {2025},
volume = {11},
number = {1},
pages = {2356--2367},
doi = {10.1109/tte.2024.3421557}
}
EUVIMED