Enhance DFIG Capability for Simultaneous Active and Reactive Currents Injection During LVRT in Weak Grid Based on Coupling Elimination
IEEE Transactions on Sustainable Energy · 2026-01 · 17 (1) · 603-619
DOI: 10.1109/tste.2025.3580060 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Sustainable Energy, 2026-01. Verfasst von Zhengqi Sui und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Key Research and Development Program of China-National Quality Infrastructure System, National Natural Science Foundation of China, CAST through Young Elite Scientists Sponsorship Program.
Abstract (Originalsprache)
The latest grid code indicates that, when a voltage drop occurs in the grid, the doubly fed induction generator (DFIG) needs to inject a certain amount of active current on the basis of meeting the reactive current demand to support frequency. However, in weak grid, further injecting active current can easily lead to small-signal instability issues. To address this, firstly, this paper analyzes the variation of the DFIG impedance with respect to changes in the current during low voltage ride through (LVRT). The result shows that, with the injection of active current, the phase of the DFIG output impedance decreases, which further reduces the system phase margin. Furthermore, this paper explains the reason for this change through theoretical deduction. Secondly, a q-axis voltage compensation-based control method is proposed. This method effectively eliminates the coupling of the DFIG impedance with current and the phase-locked loop (PLL), increasing the magnitude and phase of the impedance. Compared with existing methods, this method can significantly improve the operational capability of the DFIG during LVRT in weak grid, where both active and reactive currents are simultaneously injected. Furthermore, even if the system lacks fault detection capabilities, this method can still ensure stable operation of the DFIG under full active current injection condition during LVRT. Finally, the effectiveness and superiority of the proposed method are validated through simulations and experiments.
Förderung
- National Key Research and Development Program of China-National Quality Infrastructure System
- National Natural Science Foundation of China
- CAST through Young Elite Scientists Sponsorship Program
- Basic and Applied Basic Research Foundation of Guangdong Province
- Fundamental Research Funds for the Central Universities in China
- Liaoning Provincial Science and Technology Program-Natural Science Foundation of the Department of Science and Technology
- China Postdoctoral Science Foundation
Zitieren
APA
Sui, Z., Sun, Q., Wang, R., Shen, Q., Li, D., & Wang, P. (2026). Enhance DFIG Capability for Simultaneous Active and Reactive Currents Injection During LVRT in Weak Grid Based on Coupling Elimination. IEEE Transactions on Sustainable Energy, 17(1), 603-619. https://doi.org/10.1109/tste.2025.3580060
Vancouver
Sui Z, Sun Q, Wang R, Shen Q, Li D, Wang P. Enhance DFIG Capability for Simultaneous Active and Reactive Currents Injection During LVRT in Weak Grid Based on Coupling Elimination. IEEE Transactions on Sustainable Energy. 2026;17(1):603-619. doi:10.1109/tste.2025.3580060
BibTeX
@article{Sui2026,
author = {Sui, Zhengqi and Sun, Qiuye and Wang, Rui and Shen, Qianxiang and Li, Dashuang and Wang, Peng},
title = {Enhance DFIG Capability for Simultaneous Active and Reactive Currents Injection During LVRT in Weak Grid Based on Coupling Elimination},
journal = {IEEE Transactions on Sustainable Energy},
year = {2026},
volume = {17},
number = {1},
pages = {603--619},
doi = {10.1109/tste.2025.3580060}
}
EUVIMED