EUVIMEDEUVIMED entdecken
Crossref

High-Precision Acoustic Image Reconstruction for Uneven Surfaces Using a YOLO-Based Approach

Thi Thu Ha Vu, Tan Hung Vo, Jaeyeop Choi, Sudip Mondal, Junghwan Oh

IEEE Transactions on Semiconductor Manufacturing · 2026-08 · 39 (3) · 441-452

DOI: 10.1109/tsm.2026.3691744 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Semiconductor Manufacturing, 2026-08. Verfasst von Thi Thu Ha Vu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Research Foundation of Korea, Korean Government Ministry of Science and ICT, Pukyong National University Industry-University Cooperation Foundation’s 2024 Post-Doc Support Project..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

C-scan images in scanning acoustic microscopy (SAM) are crucial for ensuring the reliability and accuracy of semiconductor devices. These images provide detailed cross-sectional views of devices, allowing for precise identification and analysis of internal structures and defects without causing any damage. Recent studies have extensively employed C-scan imaging to enhance quality control processes, significantly improving the overall effectiveness of non-destructive testing (NDT). However, most samples typically possess flat surfaces and are examined under optimal scanning conditions. This article addresses the challenge of uneven or deformed sample surfaces that result in low-quality C-scan images. Specifically, we developed a surface segmentation model utilizing B-scan images from the SAM system and a fine-tuned version of the latest You Only Look Once (YOLO) architecture. Subsequently, the A-scan was recalculated to reconstruct the C-scan image. To evaluate the feasibility of this approach, we posed two research questions: 1) Can the improved YOLOv11-seg network effectively perform surface segmentation? and 2) How is the quality of the C-scan image improved after reconstruction? The results indicate that our enhanced model achieves promising performance in surface segmentation of B-scan images, with a mean Average Precision $mAP_{0.5-0.95}$ of approximately 0.938 for bounding boxes and 0.901 for masks. This study proposes an effective solution for the NDT of semiconductor samples with uneven surfaces that ensures high-quality C-scan images, supports quality control processes, and enhances the overall effectiveness of non-destructive evaluation methodologies.

Förderung

  • National Research Foundation of Korea
  • Korean Government Ministry of Science and ICT
  • Pukyong National University Industry-University Cooperation Foundation’s 2024 Post-Doc Support Project.

Zitieren

APA

Vu, T. T. H., Vo, T. H., Choi, J., Mondal, S., & Oh, J. (2026). High-Precision Acoustic Image Reconstruction for Uneven Surfaces Using a YOLO-Based Approach. IEEE Transactions on Semiconductor Manufacturing, 39(3), 441-452. https://doi.org/10.1109/tsm.2026.3691744

Vancouver

Vu TTH, Vo TH, Choi J, Mondal S, Oh J. High-Precision Acoustic Image Reconstruction for Uneven Surfaces Using a YOLO-Based Approach. IEEE Transactions on Semiconductor Manufacturing. 2026;39(3):441-452. doi:10.1109/tsm.2026.3691744

BibTeX
@article{Vu2026,
  author = {Vu, Thi Thu Ha and Vo, Tan Hung and Choi, Jaeyeop and Mondal, Sudip and Oh, Junghwan},
  title = {High-Precision Acoustic Image Reconstruction for Uneven Surfaces Using a YOLO-Based Approach},
  journal = {IEEE Transactions on Semiconductor Manufacturing},
  year = {2026},
  volume = {39},
  number = {3},
  pages = {441--452},
  doi = {10.1109/tsm.2026.3691744}
}
Kostenlos starten →