EUVIMEDEUVIMED entdecken
Crossref

Fuzzy Granulation Interval-Based Fault Diagnosis Method for Ring-Type DC Microgrid

Hongyi Liu, Hua Han, Xinlong Zheng, Yao Sun, Mei Su, Tao Ling, Xubin Liu

IEEE Transactions on Smart Grid · 2024-07 · 15 (4) · 3402-3417

DOI: 10.1109/tsg.2024.3359635 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Smart Grid, 2024-07. Verfasst von Hongyi Liu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Technology Research and Development Program of Hunan Province of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The lack of relevant protection schemes and standards brings significant challenges to the promotion of direct current microgrid (DCMG) technologies. The existing line fault diagnosis methods usually require additional measuring devices to obtain fault signals. Although reducing the number of sensors can lower the system costs, it also increases the difficulty of diagnosis. Pole-to-pole (PP) and positive pole-to-ground (PPG) fault classification under unknown fault resistance, and negative-to-ground (NPG) fault detection under unobvious positive pole current characteristics are two major difficulties. To solve the above issues, a fuzzy granulation interval (FGI) theory-based line fault diagnosis method is proposed in this paper. Only locally measured bus-side voltage and positive pole current signals shared with the converter controller inputs are required. Firstly, the fault characteristics and diagnosis difficulties are analyzed. Then a new NPG fault index interval range (IR) is designed to extract the abnormal post-fault voltage fluctuations. Moreover, the PP/PPG fault classification strategy is designed according to the interval characteristics and capacitor discharge process. Finally, the performance of the proposed method has been evaluated through MATLAB/Simulink simulations and hardware-in-the-loop (HIL) tests. The results demonstrate that the proposed method can accurately discriminate different line faults within 1.5 ms under different fault conditions.

Förderung

  • National Natural Science Foundation of China
  • Key Technology Research and Development Program of Hunan Province of China

Zitieren

APA

Liu, H., Han, H., Zheng, X., Sun, Y., Su, M., Ling, T., & Liu, X. (2024). Fuzzy Granulation Interval-Based Fault Diagnosis Method for Ring-Type DC Microgrid. IEEE Transactions on Smart Grid, 15(4), 3402-3417. https://doi.org/10.1109/tsg.2024.3359635

Vancouver

Liu H, Han H, Zheng X, Sun Y, Su M, Ling T, et al. Fuzzy Granulation Interval-Based Fault Diagnosis Method for Ring-Type DC Microgrid. IEEE Transactions on Smart Grid. 2024;15(4):3402-3417. doi:10.1109/tsg.2024.3359635

BibTeX
@article{Liu2024,
  author = {Liu, Hongyi and Han, Hua and Zheng, Xinlong and Sun, Yao and Su, Mei and Ling, Tao and Liu, Xubin},
  title = {Fuzzy Granulation Interval-Based Fault Diagnosis Method for Ring-Type DC Microgrid},
  journal = {IEEE Transactions on Smart Grid},
  year = {2024},
  volume = {15},
  number = {4},
  pages = {3402--3417},
  doi = {10.1109/tsg.2024.3359635}
}