EUVIMEDEUVIMED entdecken
Crossref

Ultra-High Spatial Resolution PET/Compton Detector Based on 0.32 mm Pitch GAGG Array

Jiahao Xie, Haibo Wang, Jinyi Qi, Simon R. Cherry, Junwei Du

IEEE Transactions on Radiation and Plasma Medical Sciences · 2026 · 1-1

DOI: 10.1109/trpms.2026.3696900 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026. Verfasst von Jiahao Xie und 4 weiteren Autor:innen. Gefördert von: National Institutes of Health.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Positron emission tomography (PET)/Compton hybrid imaging has the potential to become a transformative molecular imaging modality, leveraging the high sensitivity of PET systems and the multi-tracer capability of Compton imaging. Achieving high spatial resolution in a PET/Compton hybrid imaging system requires detectors capable of simultaneously resolving sub-millimeter crystals and maintaining high energy resolution - a critical challenge for preclinical PET/Compton systems. In this work, we developed an ultra-high-resolution detector that can be used as the scatter layer detector of a high spatial resolution PET/Compton hybrid system. This detector incorporates a 28 × 28 array of 0.26 × 0.26 × 2 mm3gadolinium aluminum gallium garnet (GAGG) elements (0.32 mm pitch) and a position-sensitive silicon photomultiplier (PS-SiPM). The detector demonstrated good performance: (1) flood histograms with clear crystal element separation, (2) an average energy resolution of 12.1 ± 1.8% at 511 keV, and (3) a coincidence timing resolution (CTR) of 1006 ± 78 ps obtained using a 100 - 600 keV energy window for event selection.

Förderung

  • National Institutes of Health

Zitieren

APA

Xie, J., Wang, H., Qi, J., Cherry, S. R., & Du, J. (2026). Ultra-High Spatial Resolution PET/Compton Detector Based on 0.32 mm Pitch GAGG Array. IEEE Transactions on Radiation and Plasma Medical Sciences, 1-1. https://doi.org/10.1109/trpms.2026.3696900

Vancouver

Xie J, Wang H, Qi J, Cherry SR, Du J. Ultra-High Spatial Resolution PET/Compton Detector Based on 0.32 mm Pitch GAGG Array. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026:1-1. doi:10.1109/trpms.2026.3696900

BibTeX
@article{Xie2026,
  author = {Xie, Jiahao and Wang, Haibo and Qi, Jinyi and Cherry, Simon R. and Du, Junwei},
  title = {Ultra-High Spatial Resolution PET/Compton Detector Based on 0.32 mm Pitch GAGG Array},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2026},
  pages = {1--1},
  doi = {10.1109/trpms.2026.3696900}
}
Kostenlos starten →