Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-11 · 10 (8) · 1289-1308
DOI: 10.1109/trpms.2026.3664740 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-11. Verfasst von Yuemeng Feng und 3 weiteren Autor:innen. Die Arbeit nennt 59 Literaturangaben. Gefördert von: General Electric, National Cancer Institute, NIH.
Abstract (Originalsprache)
In this study, we introduce a Compton camera system design for whole-body imaging of Actinium-225 (225Ac), one of the trending radionuclides for targeted alpha therapy (TAT). The system enables multi-energy gamma photon detection with higher efficiency compared to mechanically collimated SPECT. This design consists of two detectors made of Cadmium zinc telluride (CZT), providing a field of view (FOV) adequate for whole-body imaging, while achieving high sensitivity and clinically usable imaging resolution within a reasonable scanning time. This work focuses on the system design and evaluation using the Monte Carlo simulation toolkit GATE. The imaging performance is evaluated at two energy peaks (218 keV, 440 keV) by applying the energy windows of 211-225 keV and 430-450 keV, representing the major detectable gamma energies generated from225Ac. We explore the possibility of using the Compton camera system for treatment response monitoring in TAT. The full decay chain of225Ac is simulated. Results demonstrate an image resolution of 1.0 cm using a NEMA IQ phantom with 5.7 MBq of225Ac simulated in a cold background. An image resolution of 1.3 cm can be achieved with a hot-to-background ratio of 30:1, and a resolution of 3.7 cm can be achieved with an activity ratio of 12:1. The best achievable sensitivity at a 10 cm distance from the detector is 0.5% at 218 keV and 0.45% at 440 keV as calculated using a pure gamma source in the simulation. The proposed system may serve as an alternative imaging tool for TAT scanning in clinical settings.
Förderung
- General Electric
- National Cancer Institute
- NIH
Zitieren
APA
Feng, Y., Sitek, A., Esfahani, S. A., & Sabet, H. (2026). Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(8), 1289-1308. https://doi.org/10.1109/trpms.2026.3664740
Vancouver
Feng Y, Sitek A, Esfahani SA, Sabet H. Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(8):1289-1308. doi:10.1109/trpms.2026.3664740
BibTeX
@article{Feng2026,
author = {Feng, Yuemeng and Sitek, Arkadiusz and Esfahani, Shadi Abdar and Sabet, Hamid},
title = {Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {8},
pages = {1289--1308},
doi = {10.1109/trpms.2026.3664740}
}
EUVIMED