TIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-11 · 10 (8) · 1309-1320
DOI: 10.1109/trpms.2026.3659489 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-11. Verfasst von A. André und 16 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Union through the European Research Council (ERC) Project Prompt Gamma Time Imaging, European Union’s Horizon 2020 Research and Innovation Programme "Heavy Ion Therapy Research Integration" (HITRI)plus via the Transnational Access (TNA) Framewo….
Abstract (Originalsprache)
We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF2 crystal (2 × 1.5 × 1.5 cm3) coupled to a 2 × 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF2allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2σ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of ~ 107protons.
Förderung
- Union through the European Research Council (ERC) Project Prompt Gamma Time Imaging
- European Union’s Horizon 2020 Research and Innovation Programme "Heavy Ion Therapy Research Integration" (HITRI)plus via the Transnational Access (TNA) Framewo…
Zitieren
APA
André, A., Pinson, M., Hoarau, C., Boursier, Y., Dupont, M., Martel, L. G., Martel, M. G., Garnier, A., Hérault, J., Hofverberg, J., Kavrigin, P., Morel, C., Muraz, J., Pullia, M., Savazzi, S., Maneval, D., & Marcatili, S. (2026). TIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(8), 1309-1320. https://doi.org/10.1109/trpms.2026.3659489
Vancouver
André A, Pinson M, Hoarau C, Boursier Y, Dupont M, Martel LG, et al. TIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(8):1309-1320. doi:10.1109/trpms.2026.3659489
BibTeX
@article{Andr2026,
author = {André, A. and Pinson, M. and Hoarau, C. and Boursier, Y. and Dupont, M. and Martel, L. Gallin and Martel, M.-L. Gallin and Garnier, A. and Hérault, J. and Hofverberg, J.-P. and Kavrigin, P. and Morel, C. and Muraz, J.-F. and Pullia, M. and Savazzi, S. and Maneval, D. and Marcatili, S.},
title = {TIARA: A Fast Gamma-Ray Detector for Range Monitoring in Proton Therapy},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {8},
pages = {1309--1320},
doi = {10.1109/trpms.2026.3659489}
}