EUVIMEDEUVIMED entdecken
Open Access

Patlak-Guided Self-Supervised Learning for Dynamic PET Denoising

Qiong Liu, Xueqi Guo, Yu-Jung Tsai, Jean-Dominique Gallezot, Ming-Kai Chen, Liang Guo, Huidong Xie, Vladimir Panin, Richard E Carson, Chi Liu

IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-09 · 10 (7) · 1037-1048

DOI: 10.1109/trpms.2026.3656480 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-09. Verfasst von Qiong Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative 18F-FDG Patlak K i images provide physiologically meaningful measures of glucose influx, but they are substantially noisier than SUV images because they are estimated from short-duration dynamic frames. This study aims to improve the quality and quantitative reliability of K i images by applying a self-supervised deep learning framework for dynamic PET denoising. We propose the Patlak-Guided Self-Supervised Denoising Network (PG-SSDNet), a multi-frame CycleGAN-based model that incorporates a Patlak consistency loss to preserve tracer kinetics across frames. PG-SSDNet was evaluated on 14-frame and 6-frame whole-body 18F-FDG dynamic PET datasets from 27 patients. Performance was compared with a supervised U-Net, a single-frame CycleGAN, and a multi-frame CycleGAN without Patlak guidance. Metrics included mean normalized residual sum of squares (MNRSS) of Patlak fits, liver normalized standard deviation (NSTD), and lesion signal-to-noise ratio (SNR). PG-SSDNet consistently reduced noise while maintaining kinetic fidelity. It achieved the lowest Patlak fitting errors (MNRSS: 0.98% ± 0.14% for 14 frames, 0.85% ± 0.11% for 6 frames), the lowest liver NSTD values (0.105 ± 0.037 for 14 frames, 0.211 ± 0.107 for 6 frames), and the highest lesion SNR across all methods, while preserving accurate mean K i values. PG-SSDNet effectively denoises 18F-FDG dynamic PET data while preserving Patlak linearity, improving both lesion quantification and image quality. Unlike supervised methods, it requires no paired noisy/clean datasets, making it practical for clinical deployment. Future work will extend PG-SSDNet to other tracers with different kinetic properties and to larger multi-center datasets.

Schlagwörter

Stichwörter der Autor:innen

parametric imagingself-supervised learningwhole-body dynamic PET

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA.
  • Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA, and is now with Canon Medical Research USA, Vernon Hill, IL, 60061, USA.
  • Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA.
  • Siemens Medical Solutions USA, Inc., Knoxville, TN, 37932, USA.
  • Department of Biomedical Engineering and the Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA.

Förderung

  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Liu, Q., Guo, X., Tsai, Y. J., Gallezot, J. D., Chen, M. K., Guo, L., Xie, H., Panin, V., Carson, R. E., & Liu, C. (2026). Patlak-Guided Self-Supervised Learning for Dynamic PET Denoising. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(7), 1037-1048. https://doi.org/10.1109/trpms.2026.3656480

Vancouver

Liu Q, Guo X, Tsai YJ, Gallezot JD, Chen MK, Guo L, et al. Patlak-Guided Self-Supervised Learning for Dynamic PET Denoising. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(7):1037-1048. doi:10.1109/trpms.2026.3656480

BibTeX
@article{Liu2026,
  author = {Liu, Qiong and Guo, Xueqi and Tsai, Yu-Jung and Gallezot, Jean-Dominique and Chen, Ming-Kai and Guo, Liang and Xie, Huidong and Panin, Vladimir and Carson, Richard E and Liu, Chi},
  title = {Patlak-Guided Self-Supervised Learning for Dynamic PET Denoising},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2026},
  volume = {10},
  number = {7},
  pages = {1037--1048},
  doi = {10.1109/trpms.2026.3656480}
}
Kostenlos starten →