Sensitivity and Count Rate Performance Studies of the BrainPET-7T Insert With 18 F, 124 I, and 22 Na

Debora Niekämper, Lutz Tellmann, Jürgen J. Scheins, Chris Hoffmann, Stefan Spellerberg, Elisabeth Pfaehler, Natia Beriashvili, Keith George Ciantar, N. Jon Shah, Christoph Lerche

IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-09 · 10 (7) · 1152-1160

DOI: 10.1109/trpms.2025.3650091 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-09. Verfasst von Debora Niekämper und 9 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The BrainPET-7T insert is designed for simultaneous human-brain PET imaging with ultra-high-field MRI. It offers a high sensitivity and signal-to-noise ratio by detector blocks of pixelated LSO scintillators with a height of 2.4cm, digital silicon photomultiplier readout, and enhanced data processing methods. This makes it particulary interesting for +--emitter applications, such as dual-isotope imaging, which rely on the detection of triple coincidences. We investigated the scanner sensitivity using the isotopes 124I and 22Na, in comparison to 18F. Count rate performance was assessed using 124I and 18F for different energy window settings with an analysis following the NEMA NU 2-2018 protocol. For the count rate determination, an adapted strategy for estimating the scatter fraction for +--emitters was applied. The peak double coincidence sensitivity for 18F measured at the center and off-center was between 10.16(8)% and 12.37(10)% for energy windows of 440 to 594keV and 420 to 650keV. The true triple sensitivities obtained at the isocenter were 3.13(9)% and 4.88(12)% for 124I and between 0.8662(23)% and 3.112(5)% for 22Na depending on the selected energy window and rejection rule. The maximum RNEC of the 18F-measurement was 276kcps at 16.3kBqmL-1, while the maximum Rtrue was 780kcps at 22.7kBqmL-1 for an energy window of 440 to 594keV. The scatter fraction ranged from 28% to 33% and the random fraction from 3% to 40%. In the case of 124I, the ratio of estimated true triples to doubles was ≈6%, with a higher random fraction of 27% for triples compared to 2.8% for doubles. These results demonstrate the potential feasibility of employing the BrainPET-7T insert for +--emitter applications.

Zitieren

APA

Niekämper, D., Tellmann, L., Scheins, J. J., Hoffmann, C., Spellerberg, S., Pfaehler, E., Beriashvili, N., Ciantar, K. G., Shah, N. J., & Lerche, C. (2026). Sensitivity and Count Rate Performance Studies of the BrainPET-7T Insert With 18 F, 124 I, and 22 Na. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(7), 1152-1160. https://doi.org/10.1109/trpms.2025.3650091

Vancouver

Niekämper D, Tellmann L, Scheins JJ, Hoffmann C, Spellerberg S, Pfaehler E, et al. Sensitivity and Count Rate Performance Studies of the BrainPET-7T Insert With 18 F, 124 I, and 22 Na. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(7):1152-1160. doi:10.1109/trpms.2025.3650091

BibTeX
@article{Niekmper2026,
  author = {Niekämper, Debora and Tellmann, Lutz and Scheins, Jürgen J. and Hoffmann, Chris and Spellerberg, Stefan and Pfaehler, Elisabeth and Beriashvili, Natia and Ciantar, Keith George and Shah, N. Jon and Lerche, Christoph},
  title = {Sensitivity and Count Rate Performance Studies of the BrainPET-7T Insert With 18 F, 124 I, and 22 Na},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2026},
  volume = {10},
  number = {7},
  pages = {1152--1160},
  doi = {10.1109/trpms.2025.3650091}
}
Kostenlos starten →