EUVIMEDEUVIMED entdecken
Crossref

On the Benefits of Quantum Entanglement and Compton Kinematics for Scatter Discrimination in PET Imaging

M. Moulin, G. Montémont, S. Stanchina, J. M. Létang

IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-07 · 10 (6) · 930-941

DOI: 10.1109/trpms.2025.3649798 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-07. Verfasst von M. Moulin und 3 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper compares methods for rejecting in-patient scattered photons in PET instruments, which can degrade image quality by introducing bias and noise. The focus is on events where both annihilation photons interact several times in the detection medium. Compton scattering physics and annihilation photon polarization entanglement are utilized. Events are classified by the number of hits in the detector to assess information quality, and the spatial response from lines of response or Compton cones is analysed. A comparison between methods is made through a simulation of an ideal cylindrical detector with a radius of 15 cm and a thickness of 1 cm, using Geant4. Results from the simulations are used to create histograms for the different observables. Metrics, such as receiver-operating-characteristic (ROC) curves and noise equivalent count (NEC), are used to quantify the efficiency of each method and the influence of hit multiplicity. Alongside this simulation-based investigation, an experiment using a pair of CdZnTe Compton cameras has been set up to validate the entanglement model and its integration simulation. We demonstrate that entanglement information may be considered less valuable, achieving an area under the ROC curve of 52% compared to energy deposition and Compton kinematics, which have an area of 97%. Finally, the obtained detective quantum efficiency (DQE) demonstrates the superiority of Compton cones for low resolution, up to around 0.05 cm-1, followed by the line of response, which achieves a spatial bandwidth of 1.6 cm-1, thus showing the complementarity between the two types of information. This study highlights the importance of Compton kinematics and the limited value of entanglement for rejecting scattered events.

Zitieren

APA

Moulin, M., Montémont, G., Stanchina, S., & Létang, J. M. (2026). On the Benefits of Quantum Entanglement and Compton Kinematics for Scatter Discrimination in PET Imaging. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(6), 930-941. https://doi.org/10.1109/trpms.2025.3649798

Vancouver

Moulin M, Montémont G, Stanchina S, Létang JM. On the Benefits of Quantum Entanglement and Compton Kinematics for Scatter Discrimination in PET Imaging. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(6):930-941. doi:10.1109/trpms.2025.3649798

BibTeX
@article{Moulin2026,
  author = {Moulin, M. and Montémont, G. and Stanchina, S. and Létang, J. M.},
  title = {On the Benefits of Quantum Entanglement and Compton Kinematics for Scatter Discrimination in PET Imaging},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2026},
  volume = {10},
  number = {6},
  pages = {930--941},
  doi = {10.1109/trpms.2025.3649798}
}
Kostenlos starten →