EUVIMEDEUVIMED entdecken
Crossref

Epitaxial Quenching Resistor SiPM With Counting Rate Enhanced Technique Aiming at Photon-Counting CT Applications

Yongqiang Yan, Lin Zhang, Tianyu Yuan, Tianxi Sun, Kun Liang, Ru Yang, Dejun Han

IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-07 · 10 (6) · 942-950

DOI: 10.1109/trpms.2025.3640670 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-07. Verfasst von Yongqiang Yan und 6 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a high-performance photon-counting detector (PCD) for photon-counting computed tomography (PCCT) applications, addressing the critical challenge of pulse pile-up at high X-ray photon fluxes. The PCD is composed of a fast Lu1.8Y0.2SiO5:Ce (LYSO) scintillator with an epitaxial quenching resistor type silicon photomultiplier (EQR SiPM), which features a small microcell pitch of 10 μm, a small active area of 0.52 × 0.52 mm2 and high fill factor of 49%. It exhibits a rapid recovery time of 1.85 ns and high photon detection efficiency (PDE) greater than 30%, thus is able to achieve a high photon counting rate while retaining adequate high energy resolution. In order to further mitigate pile-up effects, a pole-zero cancellation (PZC) circuit was implemented to narrow pulse width from 46.1 ns to 19.5 ns (FWHM) along with a Pileup Recovery Algorithm (PRA) for pileup pulse discrimination. Experimental results demonstrate an energy resolution of 37.7%(FWHM) at 59.5 keV (241Am, 24 kBq) and a maximum count rate of 102.7 Mcps/mm2 under 80kV X-ray irradiation. This count rate was twice as high as that obtained without using PRA methods. These preliminary results indicate the feasibility of EQR-SiPM based scintillation PCDs in clinical PCCT. The results demonstrate the PPR method’s efficacy in improving spectral performance under high flux conditions in a laboratory setting, though its clinical scalability remains challenging

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Yan, Y., Zhang, L., Yuan, T., Sun, T., Liang, K., Yang, R., & Han, D. (2026). Epitaxial Quenching Resistor SiPM With Counting Rate Enhanced Technique Aiming at Photon-Counting CT Applications. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(6), 942-950. https://doi.org/10.1109/trpms.2025.3640670

Vancouver

Yan Y, Zhang L, Yuan T, Sun T, Liang K, Yang R, et al. Epitaxial Quenching Resistor SiPM With Counting Rate Enhanced Technique Aiming at Photon-Counting CT Applications. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(6):942-950. doi:10.1109/trpms.2025.3640670

BibTeX
@article{Yan2026,
  author = {Yan, Yongqiang and Zhang, Lin and Yuan, Tianyu and Sun, Tianxi and Liang, Kun and Yang, Ru and Han, Dejun},
  title = {Epitaxial Quenching Resistor SiPM With Counting Rate Enhanced Technique Aiming at Photon-Counting CT Applications},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2026},
  volume = {10},
  number = {6},
  pages = {942--950},
  doi = {10.1109/trpms.2025.3640670}
}
Kostenlos starten →