Evaluation of a PET Insert for Trimodal Imaging: A Step Toward PET/MRI-Guided Focused Ultrasound
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-05 · 10 (5) · 789-798
DOI: 10.1109/trpms.2025.3615467 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-05. Verfasst von F Lopez-Berenguer und 34 weiteren Autor:innen. Beteiligte Einrichtung: Detectors for Molecular Imaging Laboratory, Institute of Instruments for Molecular Imaging, 46022 Valencia, Spain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NIBIB NIH HHS, NCI NIH HHS.
Abstract (Originalsprache)
Combining positron emission tomography (PET) with magnetic resonance imaging (MRI) and focused ultrasound (FUS) has emerged as a promising hybrid technique in the medical imaging field. Despite the potential benefits of using simultaneous PET and MRI acquisitions to monitor therapeutic effects and ensure precision and safety during FUS applications, no commercial or academic PET/MRI-guided FUS system (referred in the following as trimodal PET-MRI-FUS) exists. This work presents the design and evaluation of a preclinical PET insert for simultaneous operation with MRI and FUS systems. The proposed PET insert is based on monolithic LYSO crystals arranged in two octagonal rings that define inner and outer diameters of 72 and 114 mm, respectively, with an axial length of 67 mm. The system performance was evaluated according to the NEMA NU 4 2008 protocol. It achieves a uniform spatial resolution of ~0.9 mm along the whole PET Field of View (FOV) when enabling Depth of Interaction (DOI) capabilities. Moreover, we found a sensitivity peak of 3.8% for an energy window of 255-766 keV and a peak noise equivalent count rate peak of 80 kcps at an activity of 19 MBq. The compatibility of the PET insert with both low- and high-field MRI systems, as well as with custom and commercially available FUS devices, was studied using phantoms and in vivo experiments, respectively. The results of the trimodal tests have proven that the PET insert works simultaneously with both MRI and FUS systems.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Detectors for Molecular Imaging Laboratory, Institute of Instruments for Molecular Imaging, 46022 Valencia, Spain.
- Detectors for Molecular Imaging Laboratory, the Instituto de Instrumentación para Imagen Molecular, and the Centro Mixto CSIC, Universitat Politècnica de València, 46022 Valencia, Spain.
- Department of Nuclear Medicine, Hospital La Fe, 46026 Valencia, Spain.
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA 22904 USA.
- Centro Mixto CSIC and the Instituto de Instrumentación para Imagen Molecular, Universitat Politècnica de València, 46022 Valencia, Spain.
- Biomedical Engineering Society, University of Virginia, Charlottesville, VA 22904 USA.
ORCID-Profile: F Lopez-Berenguer, A Gonzalez-Montoro, M Freire, S Jiménez-Serrano, F Loignon-Houle, J V Rispoli, N Tustison, M B Williams, D Andrés, J L Alonso-Ramos, N Jiménez, J M Algarín, E Pallás, J Alonso, N D Sheybani, T Sherlock, A Thede, Z E F Demir, J M Benlloch, M J Rodríguez-Álvarez, A J González
Förderung
- NIH HHS
- NIBIB NIH HHS
- NCI NIH HHS
- Generalitat Valenciana
- University of Virginia Focused Ultrasound Cancer Immunotherapy Center and the FUS Foundation
- Spanish Ministry of Science and Innovation and the European Social Fund Project
Zitieren
APA
Lopez-Berenguer, F., Gonzalez-Montoro, A., Freire, M., González-Tamarit, A., Jiménez-Serrano, S., Vidal, L. F., Gil, M., Loignon-Houle, F., Torres, I., Sachs, J. L., Rispoli, J. V., Tustison, N., Berr, S. S., Williams, M. B., Andrés, D., Rodríguez-García, J. J., Alonso-Ramos, J. L., Jiménez, N., Carrión, A., …, & González, A. J. (2026). Evaluation of a PET Insert for Trimodal Imaging: A Step Toward PET/MRI-Guided Focused Ultrasound. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(5), 789-798. https://doi.org/10.1109/trpms.2025.3615467
Vancouver
Lopez-Berenguer F, Gonzalez-Montoro A, Freire M, González-Tamarit A, Jiménez-Serrano S, Vidal LF, et al. Evaluation of a PET Insert for Trimodal Imaging: A Step Toward PET/MRI-Guided Focused Ultrasound. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(5):789-798. doi:10.1109/trpms.2025.3615467
BibTeX
@article{LopezBerenguer2026,
author = {Lopez-Berenguer, F and Gonzalez-Montoro, A and Freire, M and González-Tamarit, A and Jiménez-Serrano, S and Vidal, L F and Gil, M and Loignon-Houle, F and Torres, I and Sachs, J L and Rispoli, J V and Tustison, N and Berr, S S and Williams, M B and Andrés, D and Rodríguez-García, J J and Alonso-Ramos, J L and Jiménez, N and Carrión, A and Camarena, F and Guallart-Naval, T and Algarín, J M and Bosch, R and Pallás, E and Alonso, J and Sheybani, N D and Maslova, S and Sherlock, T and Thede, A and Demir, Z E F and Hoch, M and He, J and Benlloch, J M and Rodríguez-Álvarez, M J and González, A J},
title = {Evaluation of a PET Insert for Trimodal Imaging: A Step Toward PET/MRI-Guided Focused Ultrasound},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {5},
pages = {789--798},
doi = {10.1109/trpms.2025.3615467}
}
EUVIMED