Enhancing the Diagnostic Accuracy of Amyloid PET: The Impact of MR-Guided PET Reconstruction
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-03 · 10 (3) · 344-349
DOI: 10.1109/trpms.2025.3597845 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-03. Verfasst von M Mehdi Khalighi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Stanford University, Stanford, CA, USA. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIA NIH HHS, NIBIB NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
18F-Florbetaben (FBB) uptake in the supratentorial cortex is indicative of amyloid positivity. Due to PET's low spatial resolution, image noise, and spill-over of signal from adjacent white-matter into gray-matter, trained readers may provide inconsistent reads and quantitative calculations like Centiloids (CLs) are also affected. A set of 264 18F-Florbetaben (amyloid) PET/MRI exams were reconstructed using conventional ordered subset expectation maximization (OSEM) method and MR-guided block sequential regularized expectation maximization (MRgBSREM) method. Three trained readers evaluated the images from these 264 patients, which were reconstructed using the OSEM method. Fifty-three exams were rated inconsistently and were mixed with another 53 exams which were rated consistently. These 106 subjects were then rated by our readers using the MRgBSREM PET reconstruction method. CLs were measured using both reconstruction methods. There is significant correlation between CL measured by OSEM and MRgBSREM methods with R2=0.99. The number of inconsistent exams dropped by 64% using MRgBSREM method as compared with OSEM method. Using Fleiss-Kappa statistical test, the agreement between readers was raised from "Fair" to "Significant" in the 106-subjects subset. PET reconstruction with MR priors can significantly improve the consistency of ratings among trained readers. Given the prevalence of inconsistent ratings in amyloid PET, methods that enhance the ability to distinguish intermediate amyloid levels could be valuable for the widespread adoption of this modality.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology Department, Stanford University, Stanford, CA, USA.
- Neurology Department, Stanford University, Stanford, CA, USA, she is now with Radiology and Neurology Departments, UC Davis, Davis, CA, USA.
- Neurology Department, Stanford University, Stanford, CA, USA.
Förderung
- NIA NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
- Stanford Alzheimer’s Disease Research Center
- Alzheimer’s Association
- GE HealthCare
- Life Molecular Imaging
Zitieren
APA
Khalighi, M. M., Young, C. B., Weiss, S., Zeineh, M., Davidzon, G., Mormino, E., & Zaharchuk, G. (2026). Enhancing the Diagnostic Accuracy of Amyloid PET: The Impact of MR-Guided PET Reconstruction. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(3), 344-349. https://doi.org/10.1109/trpms.2025.3597845
Vancouver
Khalighi MM, Young CB, Weiss S, Zeineh M, Davidzon G, Mormino E, et al. Enhancing the Diagnostic Accuracy of Amyloid PET: The Impact of MR-Guided PET Reconstruction. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(3):344-349. doi:10.1109/trpms.2025.3597845
BibTeX
@article{Khalighi2026,
author = {Khalighi, M Mehdi and Young, Christina B and Weiss, Skylar and Zeineh, Michael and Davidzon, Guido and Mormino, Elizabeth and Zaharchuk, Greg},
title = {Enhancing the Diagnostic Accuracy of Amyloid PET: The Impact of MR-Guided PET Reconstruction},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {3},
pages = {344--349},
doi = {10.1109/trpms.2025.3597845}
}
EUVIMED