ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-03 · 10 (3) · 359-370
DOI: 10.1109/trpms.2025.3593080 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-03. Verfasst von Yongyi Shi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Institute of Biomedical Imaging and Bioengineering/National Institutes of Health.
Abstract (Originalsprache)
Photon-counting computed tomography (PCCT) has emerged as a transformative imaging modality, enabling enhanced spatial resolution, and multi-energy acquisition with energy-discriminating detectors of significantly smaller detector elements. However, both energy discriminating power and reduced detector pixel size result in fewer detected photons per measurement, inherently increasing noise in reconstructed images. In this study, we propose ZS4D, a zero-shot self-similarity-steered denoiser for PCCT reconstruction. Specifically, a self-similarity denoiser is pre-trained in a self-supervised manner by leveraging spectral correlations through multi-energy extraction and capturing volumetric context via the complementary synergy of axial and sagittal planes. The pre-trained denoiser is then integrated as a prior into an iterative reconstruction framework, enabling effective noise suppression and structural preservation. Extensive experiments demonstrate that ZS4D adapts well to varying noise levels and significantly enhances image quality in both simulated and pre-clinical PCCT datasets. Also, ZS4D demonstrates effectiveness in deblurring tasks. Furthermore, our denoiser pretrained on clinical PCCT data is shown to enhance the spatial resolution of conventional CT images.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 USA.
- GE HealthCare Technology & Innovation Center (HTIC), Niskayuna, NY, USA.
- Biomedical Imaging Center, Rensselaer Polytechnic Institute, Troy, NY 12180. and Department of Radiology, Wake Forest University, Winston-Salem, SC 27109 USA.
Förderung
- NHLBI NIH HHS
- National Institute of Biomedical Imaging and Bioengineering/National Institutes of Health
Zitieren
APA
Shi, Y., Niu, C., Xia, W., Liang, Y., Fu, L., De Man, B., & Wang, G. (2026). ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(3), 359-370. https://doi.org/10.1109/trpms.2025.3593080
Vancouver
Shi Y, Niu C, Xia W, Liang Y, Fu L, De Man B, et al. ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(3):359-370. doi:10.1109/trpms.2025.3593080
BibTeX
@article{Shi2026,
author = {Shi, Yongyi and Niu, Chuang and Xia, Wenjun and Liang, Yuxuan and Fu, Lin and De Man, Bruno and Wang, Ge},
title = {ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {3},
pages = {359--370},
doi = {10.1109/trpms.2025.3593080}
}
EUVIMED