EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of Flexible Circuit Bonding and System Integration on Energy Resolution of Cross-Strip CZT Detectors

Emily Enlow iD, Milad Diba, James Clayton, Brian Harris iD, Shiva Abbaszadeh iD

IEEE Transactions on Radiation and Plasma Medical Sciences · 2023-07 · 7 (6) · 580-586

DOI: 10.1109/trpms.2023.3256406 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2023-07. Verfasst von Emily Enlow und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, University of California Santa Cruz, Santa Cruz, CA 95064 USA. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cadmium zinc telluride (CZT) detectors enable high spatial resolution and high detection efficiency and are utilized for many gamma-ray and X-ray spectroscopy applications. In this article, we describe a stable bonding process and report on the characterization of cross-strip CZT detectors before and after bonding to flexible circuit. The bonding process utilizes gold stud bonding and polymer epoxy technique to bond the flexible circuits to two CZT crystals and form a detector module in an anode-cathode-cathode-anode (ACCA) configuration. The readout electronics is optimized in terms of shaper setting and steering electrode voltage. The average full-width half maximum (FWHM) energy resolution at 662 keV of 110 CZT crystals tested individually was 3.5% ± 0.59% and 4.75% ± 0.48% prebonded and post-bonded, respectively. No depth correction was performed in this study. The average FWHM energy resolution at 662 keV of the scaled-up system with 80 CZT crystals was 4.40% ± 0.53%, indicating the scaled-up readout electronics and stacking of the modules does not deteriorate performance. The proper shielding and grounding of the scaled-up system slightly improved the system-wide performance. The FWHM energy resolution at 511 keV of the scaled-up system was 5.85% ± 0.73%.

Schlagwörter

Stichwörter der Autor:innen

Cadmium zinc telluride (CZT)cross-strip electrode configurationelectronics noiseenergy resolutiongold stud bonding

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, University of California Santa Cruz, Santa Cruz, CA 95064 USA.
  • Polymer Assembly Technology Inc., Rockford, MI 49341 USA.
  • Kromek, Zelienople, PA 16063 USA.

ORCID-Profile: Emily Enlow, Brian Harris, Shiva Abbaszadeh

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health

Zitieren

APA

Enlow, E., Diba, M., Clayton, J., Harris, B., & Abbaszadeh, S. (2023). Impact of Flexible Circuit Bonding and System Integration on Energy Resolution of Cross-Strip CZT Detectors. IEEE Transactions on Radiation and Plasma Medical Sciences, 7(6), 580-586. https://doi.org/10.1109/trpms.2023.3256406

Vancouver

Enlow E, Diba M, Clayton J, Harris B, Abbaszadeh S. Impact of Flexible Circuit Bonding and System Integration on Energy Resolution of Cross-Strip CZT Detectors. IEEE Transactions on Radiation and Plasma Medical Sciences. 2023;7(6):580-586. doi:10.1109/trpms.2023.3256406

BibTeX
@article{Enlow2023,
  author = {Enlow, Emily and Diba, Milad and Clayton, James and Harris, Brian and Abbaszadeh, Shiva},
  title = {Impact of Flexible Circuit Bonding and System Integration on Energy Resolution of Cross-Strip CZT Detectors},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2023},
  volume = {7},
  number = {6},
  pages = {580--586},
  doi = {10.1109/trpms.2023.3256406}
}
Kostenlos starten →