EUVIMEDEUVIMED entdecken
Crossref

Uncertainty-Aware Cross-Scale Hand-Eye Calibration of 2-D Optical Coherence Tomography Using a Plane Target

Yan Ma, Haitian Lyu, Jiewen Lai, Ruiyang Zhang, Wu Yuan, Hongliang Ren

IEEE Transactions on Robotics · 2026 · 42 · 3105-3120

DOI: 10.1109/tro.2026.3710397 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Robotics, 2026. Verfasst von Yan Ma und 5 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Hong Kong Research Grants Council, Research Impact, General Research Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical coherence tomography (OCT) delivers micrometer-resolution cross-sectional images within a millimeter-scale field of view (FOV), making precise hand-eye calibration critical when integrating OCT with robots. Yet, calibrating 2-D OCT using cross-sectional images remains an open challenge: Most existing approaches target 3-D OCT capable of volumetric imaging, while techniques for analogous 2-D sensors overlook a cross-scale issue whereby robot pose uncertainty is nonnegligible at the OCT scale. We present a novel hand-eye calibration method tailored to 2-D OCT. Using a single plane target to facilitate data collection, we explicitly model pose uncertainty for uncertainty-aware estimation using the Gauss–Helmert model. The hand-eye transformation and target parameters are jointly estimated on a composite manifold with analytical Jacobians for robust convergence. When pose covariances are unavailable, variance factors are inferred from measurements, allowing for uncertainty-aware calibration without prior knowledge of noise. Extensive simulations and hardware experiments demonstrate consistent improvements in accuracy and robustness, surpassing existing methods. Moreover, simulations at the meter-scale FOV indicate that the approach generalizes to similar 2-D sensors, such as laser profilers and 2-D light detection and ranging, with state-of-the-art accuracy.

Förderung

  • Hong Kong Research Grants Council
  • Research Impact
  • General Research Fund
  • National Natural Science Foundation of China
  • Young Scientists Fund
  • NSFC/RGC
  • Joint Research Scheme
  • Ministry of Science and Technology

Zitieren

APA

Ma, Y., Lyu, H., Lai, J., Zhang, R., Yuan, W., & Ren, H. (2026). Uncertainty-Aware Cross-Scale Hand-Eye Calibration of 2-D Optical Coherence Tomography Using a Plane Target. IEEE Transactions on Robotics, 42, 3105-3120. https://doi.org/10.1109/tro.2026.3710397

Vancouver

Ma Y, Lyu H, Lai J, Zhang R, Yuan W, Ren H. Uncertainty-Aware Cross-Scale Hand-Eye Calibration of 2-D Optical Coherence Tomography Using a Plane Target. IEEE Transactions on Robotics. 2026;42:3105-3120. doi:10.1109/tro.2026.3710397

BibTeX
@article{Ma2026,
  author = {Ma, Yan and Lyu, Haitian and Lai, Jiewen and Zhang, Ruiyang and Yuan, Wu and Ren, Hongliang},
  title = {Uncertainty-Aware Cross-Scale Hand-Eye Calibration of 2-D Optical Coherence Tomography Using a Plane Target},
  journal = {IEEE Transactions on Robotics},
  year = {2026},
  volume = {42},
  pages = {3105--3120},
  doi = {10.1109/tro.2026.3710397}
}
Kostenlos starten →