Audible Noise and Corona Discharge From Water Droplets on Superhydrophobic HVAC Conductors
IEEE Transactions on Power Delivery · 2023-12 · 38 (6) · 3771-3781
DOI: 10.1109/tpwrd.2023.3293869 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Power Delivery, 2023-12. Verfasst von Xu Zhang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: Ministry of Science and Technology of the People's Republic of China, University of Manchester.
Abstract (Originalsprache)
Audible noise from transmission lines is mainly generated by corona discharge from defects and water droplets on the conductors’ surface. Applying a superhydrophobic coating to the conductors can reduce corona discharge, thereby reducing the level of audible noise produced. In this article, corona discharge and noise measurements from an untreated conductor and a conductor coated with superhydrophobic coatings were carried out in AC electric fields and continuous water spray. The coated conductors show higher partial discharge inception voltages (PDIV) than uncoated ones. PD magnitude and PD per cycle of the coated conductors are lower compared with uncoated conductors, especially at electric fields above 14 kV/cm. A linear correlation between overall sound pressure and total PD magnitude is established. The behavior of corona discharges from single droplets with various sizes and positions and associated droplet vibration were investigated and the local electric field enhancement was analyzed by finite element analysis to examine the influence of droplet size and position on electric field distribution. Superhydrophobic coatings result in reduced PD magnitude and number and therefore reduce audible noise generated. This is attributed to small sessile droplets forming rather than large pendant droplets.
Förderung
- Ministry of Science and Technology of the People's Republic of China
- University of Manchester
Zitieren
APA
Zhang, X., Cotton, I., Rowland, S. M., Li, Q., Lian, C., Li, W., & Plaengpraphan, C. (2023). Audible Noise and Corona Discharge From Water Droplets on Superhydrophobic HVAC Conductors. IEEE Transactions on Power Delivery, 38(6), 3771-3781. https://doi.org/10.1109/tpwrd.2023.3293869
Vancouver
Zhang X, Cotton I, Rowland SM, Li Q, Lian C, Li W, et al. Audible Noise and Corona Discharge From Water Droplets on Superhydrophobic HVAC Conductors. IEEE Transactions on Power Delivery. 2023;38(6):3771-3781. doi:10.1109/tpwrd.2023.3293869
BibTeX
@article{Zhang2023,
author = {Zhang, Xu and Cotton, Ian and Rowland, Simon M. and Li, Qi and Lian, Chengxing and Li, Wenyuan and Plaengpraphan, Chorphaka},
title = {Audible Noise and Corona Discharge From Water Droplets on Superhydrophobic HVAC Conductors},
journal = {IEEE Transactions on Power Delivery},
year = {2023},
volume = {38},
number = {6},
pages = {3771--3781},
doi = {10.1109/tpwrd.2023.3293869}
}