Faulty Feeder Detection for Single Line-to-Ground Fault in Distribution Networks With DGs Based on Correlation Analysis and Harmonics Energy

Jiawei Yuan, Yanjie Hu, Yonghui Liang, Zaibin Jiao

IEEE Transactions on Power Delivery · 2023-04 · 38 (2) · 1020-1029

DOI: 10.1109/tpwrd.2022.3203992 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Power Delivery, 2023-04. Verfasst von Jiawei Yuan und 3 weiteren Autor:innen. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Faulty feeder detection helps ensure the stable operation after single line-to-ground (SLG) faults in distribution networks. However, the SLG fault currents are weak, the fault conditions are complex, and distortion of fault signals may occur owing to the effect of distributed generators (DGs), which would result in unacceptable performance of the existing detection methods. To improve the accuracy of faulty feeder detection under high penetration of DGs, this paper firstly analyzes the three-sequence networks after SLG faults occur in distribution networks with DGs connection, and points out that the DGs connection does affect the zero-sequence components when DGs are connected to the faulty feeder. Besides, the polarity differences between zero-sequence voltage (ZSV) and zero-sequence currents (ZSC) are revealed. Subsequently, variational mode decomposition is employed to characterize the overall trend of the ZSV and ZSCs, and cross-correlation analysis is applied to capture the polarity characteristics between ZSV and ZSCs. In addition, harmonics characteristics of ZSCs are used as an auxiliary criterion when ZSCs are highly distorted caused by DGs connection. Finally, both of them are utilized to construct the detection scheme. Simulation results and practical data test demonstrate the efficiency of the proposed method.

Zitieren

APA

Yuan, J., Hu, Y., Liang, Y., & Jiao, Z. (2023). Faulty Feeder Detection for Single Line-to-Ground Fault in Distribution Networks With DGs Based on Correlation Analysis and Harmonics Energy. IEEE Transactions on Power Delivery, 38(2), 1020-1029. https://doi.org/10.1109/tpwrd.2022.3203992

Vancouver

Yuan J, Hu Y, Liang Y, Jiao Z. Faulty Feeder Detection for Single Line-to-Ground Fault in Distribution Networks With DGs Based on Correlation Analysis and Harmonics Energy. IEEE Transactions on Power Delivery. 2023;38(2):1020-1029. doi:10.1109/tpwrd.2022.3203992

BibTeX
@article{Yuan2023,
  author = {Yuan, Jiawei and Hu, Yanjie and Liang, Yonghui and Jiao, Zaibin},
  title = {Faulty Feeder Detection for Single Line-to-Ground Fault in Distribution Networks With DGs Based on Correlation Analysis and Harmonics Energy},
  journal = {IEEE Transactions on Power Delivery},
  year = {2023},
  volume = {38},
  number = {2},
  pages = {1020--1029},
  doi = {10.1109/tpwrd.2022.3203992}
}
Kostenlos starten →