Metal Particle Movement and Induced Insulator Flashover Under Impact Vibration Generated By Switching Operation in GIS

Xing Li, Weidong Liu, Dengwei Ding, Yuan Xu

IEEE Transactions on Power Delivery · 2023-04 · 38 (2) · 757-766

DOI: 10.1109/tpwrd.2022.3197221 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Power Delivery, 2023-04. Verfasst von Xing Li und 3 weiteren Autor:innen. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Technological Project of State Grid Corporation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gas insulated switchgear (GIS) insulation failures occur frequently in field operations, seriously affecting the reliability of power systems. Fault statistics show that nearly half of the insulation flashover faults in field operation are strongly related to the switching operation, and metal particles are considered to be a crucial cause of flashover. The impact vibration generated by the switching operation may activate the metal particles and make them lift and jump in the GIS, reducing the insulation performance. Therefore, in this study, an experimental platform was established to simulate the impact vibration generated by the switching operation. The flashover characteristics induced by metal particles under impact vibration were studied, and the movement behavior of metal particles was also analyzed. The results show that metal particles lying on the enclosure lift under the impact vibration and then keep jumping in the GIS. These particles can jump to cause insulator flashover with high probability after the impact vibration. The longer the metal particles, the higher the probability of insulator flashover, and the shorter the average jump duration of the metal particles before the flashover. Moreover, compared with the flake particles, linear particles are more likely to cause insulator flashover after the impact vibration. This study demonstrates the mechanism of insulator flashover caused by metal particles under impact vibration, which provides a significant support for understanding the insulation failures strongly related to the switching operation in practical applications.

Förderung

  • Technological Project of State Grid Corporation of China

Zitieren

APA

Li, X., Liu, W., Ding, D., & Xu, Y. (2023). Metal Particle Movement and Induced Insulator Flashover Under Impact Vibration Generated By Switching Operation in GIS. IEEE Transactions on Power Delivery, 38(2), 757-766. https://doi.org/10.1109/tpwrd.2022.3197221

Vancouver

Li X, Liu W, Ding D, Xu Y. Metal Particle Movement and Induced Insulator Flashover Under Impact Vibration Generated By Switching Operation in GIS. IEEE Transactions on Power Delivery. 2023;38(2):757-766. doi:10.1109/tpwrd.2022.3197221

BibTeX
@article{Li2023,
  author = {Li, Xing and Liu, Weidong and Ding, Dengwei and Xu, Yuan},
  title = {Metal Particle Movement and Induced Insulator Flashover Under Impact Vibration Generated By Switching Operation in GIS},
  journal = {IEEE Transactions on Power Delivery},
  year = {2023},
  volume = {38},
  number = {2},
  pages = {757--766},
  doi = {10.1109/tpwrd.2022.3197221}
}