Development of an Advanced Experimental System for Fundamental Investigations of Glow and Arc Discharge (GADX)
IEEE Transactions on Plasma Science · 2026-07 · 54 (7) · 3677-3686
DOI: 10.1109/tps.2026.3693350 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Plasma Science, 2026-07. Verfasst von Chunjing Hao und 11 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Major National Science and Technology Infrastructure, Shanghai Sailing Program.
Abstract (Originalsprache)
Despite the recent research efforts on the steady state and pulsed mode of glow discharge, the behavior of the glow discharge below the submicrosecond time scale in DC steady state and the pulsed mode is still very poorly understood. Pulsed glow discharge has been recently introduced as a technique for preionizing a working gas to form an initial plasma in a coaxial plasma gun developed for plasma-jet magnetoinertial fusion (PJMIF). In particular, the initiation of the electron avalanche and its evolution, the onset and the nonlinear evolution of instabilities, and their self-organization behavior in pulsed glow discharges still provide ample research opportunities. To meet the needs of this research, especially within China, a new user experimental facility, named glow and arc discharge experiment (GADX), is being developed at the Center for Ultimate Energy (CUE), ShanghaiTech University, dedicated to fundamental investigations into the behavior of glow discharge in both steady state and pulsed mode, especially the early phase of the development of the discharge. As the nature of the glow discharge depends to a large extent on the power source that drives it, we have innovated a stable DC high-voltage current source with low-internal impedance, and the output voltage fluctuation is limited to within 5%. At present, diagnostics include Langmuir probes, eight-chord laser interferometry, survey spectrometer, high-framing-rate camera (1.5 million frames per second), B-dot probes, and Rogowski coils. These diagnostics are used to test and commission the system. The commissioning tests indicate that the experimental system has attained an initial operating capability of producing glow discharges at a gas pressure of 100 Pa at an applied voltage of 1 kV with peak volume electron density of $1.8 \times 10^{21}~\mathrm {m^{-3}}$ , an electron temperature in the range of 0.4–0.7 eV, and magnetic fields of 200 mT. The initial framing video indicates the possible occurrence of self-organized motions in the glow discharge. In the future, diagnostics, such as laser-induced fluorescence, Thomson scattering, and high-resolution spectroscopy, will be introduced into the system. GADX will also serve as the experimental testbed for the development of these diagnostics for various density and temperature regimes of interest to PJMIF research. In this article, the conceptual and detailed design of the experimental system are presented.
Förderung
- Major National Science and Technology Infrastructure
- Shanghai Sailing Program
Zitieren
APA
Hao, C., Thio, Y. C. F., Wu, C., Zhang, C., Du, P., Feng, W., Sun, Y., Li, M., Liu, L., Wang, S., Wu, Y., & Zhang, S. (2026). Development of an Advanced Experimental System for Fundamental Investigations of Glow and Arc Discharge (GADX). IEEE Transactions on Plasma Science, 54(7), 3677-3686. https://doi.org/10.1109/tps.2026.3693350
Vancouver
Hao C, Thio YCF, Wu C, Zhang C, Du P, Feng W, et al. Development of an Advanced Experimental System for Fundamental Investigations of Glow and Arc Discharge (GADX). IEEE Transactions on Plasma Science. 2026;54(7):3677-3686. doi:10.1109/tps.2026.3693350
BibTeX
@article{Hao2026,
author = {Hao, Chunjing and Thio, Y. C. Francis and Wu, Chaochao and Zhang, Chen and Du, Peng and Feng, Wei and Sun, Yi and Li, Mingrui and Liu, Lin and Wang, Shengli and Wu, Yaoxing and Zhang, Shuyi},
title = {Development of an Advanced Experimental System for Fundamental Investigations of Glow and Arc Discharge (GADX)},
journal = {IEEE Transactions on Plasma Science},
year = {2026},
volume = {54},
number = {7},
pages = {3677--3686},
doi = {10.1109/tps.2026.3693350}
}
EUVIMED