Multichannel Reflectometer for Core-Localized Electron Density Fluctuation Measurement on the HL-3 Tokamak
IEEE Transactions on Plasma Science · 2026-06 · 54 (6) · 3023-3028
DOI: 10.1109/tps.2026.3693259 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Plasma Science, 2026-06. Verfasst von P. W. Shi und 6 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Central Guidance for Local Science and Technology Development Fund Projects.
Abstract (Originalsprache)
A novel multichannel microwave reflectometer has been developed for core-localized density fluctuation measurement on the HL-3 tokamak. The microwave diagnostic is characterized by having 16 independent microwave sources, achieving beam separation or combination through a multiplexer technique, and optimizing signal quality via remote control of amplifiers. Sixteen working points are arranged in a wide frequency region of 50–75 GHz, so that the microwave diagnostic has a large measurement range. Depending on detail requirement of tokamak operation, the reflectometer can work with ordinary or extraordinary waves. It is sensitive to density fluctuation and the corresponding maximum measurable wavenumber reaches $2.16~\rm cm^{-1}$ . Recently, the microwave reflectometer has been installed on HL-3 tokamak and utilized to measure the spatial location of pressure gradient-driven kinetic ballooning modes.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Central Guidance for Local Science and Technology Development Fund Projects
- Fundamental Research Program of China National Nuclear Corporation
- Innovation Program of Southwestern Institute of Physics
Zitieren
APA
Shi, P. W., Yang, Z. C., Chen, W., Hu, L. W., Liang, A. S., Jiang, M., & Shi, Z. B. (2026). Multichannel Reflectometer for Core-Localized Electron Density Fluctuation Measurement on the HL-3 Tokamak. IEEE Transactions on Plasma Science, 54(6), 3023-3028. https://doi.org/10.1109/tps.2026.3693259
Vancouver
Shi PW, Yang ZC, Chen W, Hu LW, Liang AS, Jiang M, et al. Multichannel Reflectometer for Core-Localized Electron Density Fluctuation Measurement on the HL-3 Tokamak. IEEE Transactions on Plasma Science. 2026;54(6):3023-3028. doi:10.1109/tps.2026.3693259
BibTeX
@article{Shi2026,
author = {Shi, P. W. and Yang, Z. C. and Chen, W. and Hu, L. W. and Liang, A. S. and Jiang, M. and Shi, Z. B.},
title = {Multichannel Reflectometer for Core-Localized Electron Density Fluctuation Measurement on the HL-3 Tokamak},
journal = {IEEE Transactions on Plasma Science},
year = {2026},
volume = {54},
number = {6},
pages = {3023--3028},
doi = {10.1109/tps.2026.3693259}
}
EUVIMED