EUVIMEDEUVIMED entdecken
Crossref

Development of an SRAM Neutron Detector for Pulsed Fusion Experiments

Wolfgang Hennig, Nate Kaneshige, Sara Alawabdeh, Dan Cech, Michael Hua

IEEE Transactions on Plasma Science · 2026-06 · 54 (6) · 2426-2430

DOI: 10.1109/tps.2026.3679964 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Plasma Science, 2026-06. Verfasst von Wolfgang Hennig und 4 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Gefördert von: Helion Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Radiation is known to cause single-event upsets in semiconductor devices, which leads to data errors in SRAM memory (bitflips). While usually undesirable, this effect can also be used as a mechanism to detect radiation, in particular neutrons. Previous research shows that SRAM memory is capable of detecting neutrons without permanent damage to the device, and that devices from different processes and/or manufacturers vary in properties such as neutron interaction energy threshold and overall cross section. In the work described here, an SRAM bit flip neutron detector was assembled, programmed, and tested with a variety of sources. Two SRAM types with identical chip package and functionality, from Renesas and Integrated Silicon Solution Inc. (ISSI), were tested with a Cf-252 source, deuterium-deuterium (DD) and deuterium-tritium (DT) neutron generators, and high-yield neutron pulses from the Godiva (fission) and Z-pinch experimental underground system (ZEUS) (DT fusion) facilities. Additional tests were performed with decapsulated chips and an alpha source. We observe that the number of bitflips increases linearly with the neutron fluence. The ISSI SRAM is physically a smaller die, but shows $2\times $ – $100\times $ more bit flips per neutron than the Renesas SRAM, depending on the neutron source. The bitflips are distributed randomly across memory addresses, except for groups of three close neighbors observed in the Renesas SRAM. No damage to the SRAM has been observed, even in the intense EMI and high instantaneous flux of the ZEUS pulsed neutron fields. With a suitable calibration for bitflips per incident neutrons, the detector can be used for quantitative measurements, and there is potential to use the ISSI versus Renesas type to differentiate between DT and DD neutrons. With a cost of

Förderung

  • Helion Energy

Zitieren

APA

Hennig, W., Kaneshige, N., Alawabdeh, S., Cech, D., & Hua, M. (2026). Development of an SRAM Neutron Detector for Pulsed Fusion Experiments. IEEE Transactions on Plasma Science, 54(6), 2426-2430. https://doi.org/10.1109/tps.2026.3679964

Vancouver

Hennig W, Kaneshige N, Alawabdeh S, Cech D, Hua M. Development of an SRAM Neutron Detector for Pulsed Fusion Experiments. IEEE Transactions on Plasma Science. 2026;54(6):2426-2430. doi:10.1109/tps.2026.3679964

BibTeX
@article{Hennig2026,
  author = {Hennig, Wolfgang and Kaneshige, Nate and Alawabdeh, Sara and Cech, Dan and Hua, Michael},
  title = {Development of an SRAM Neutron Detector for Pulsed Fusion Experiments},
  journal = {IEEE Transactions on Plasma Science},
  year = {2026},
  volume = {54},
  number = {6},
  pages = {2426--2430},
  doi = {10.1109/tps.2026.3679964}
}
Kostenlos starten →