Design and Implementation of Fast Transient Overvoltage Protection Systems for SPIDER Power Supplies
IEEE Transactions on Plasma Science · 2026-06 · 54 (6) · 2834-2841
DOI: 10.1109/tps.2026.3676325 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Plasma Science, 2026-06. Verfasst von Mattia Dan und 11 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben. Gefördert von: EUROfusion Consortium through European Union via the Euratom Research and Training Program, EUROfusion, International Thermonuclear Experimental Reactor (ITER) Reversed Field eXperiment (RFX) Neutral Beam Testing Facility (NBTF) Agreement from the ITER Organizati….
Abstract (Originalsprache)
Source for production of ions of deuterium extracted from RF plasma (SPIDER), the full-scale prototype of the ITER ion source operated at the Neutral Beam Test Facility in Padua, Italy, experiences frequent high-voltage breakdowns between accelerator grids, which generate electrical fast transients on the power supply system. These events are driven by the discharge of the electrostatic energy of the high-voltage system through a strongly interconnected power plant and can overstress components, especially under very high breakdown repetition rates. This article investigates two critical issues and presents the design and in-plant validation of dedicated mitigation measures. First, an impulse phase-to-neutral overvoltage on the 6.6 kV AC medium-voltage (MV) supply network feeding the ion source and extraction grid (EG) power supplies (ISEPSs) is explained through circuit modeling calibrated on dedicated tests; capacitor-based protection modules installed in the plant reduce the peak below the specified limit and are validated during plant commissioning. Second, accelerator breakdowns produce overvoltage surges at the output of the EG power supply that exceed component ratings when conventional varistor clamps are used. A fully passive semiconductor-based protection with external energy-absorbing resistors is developed, distributed over multiple installation points to share surge currents, and tuned through on-system breakdown testing. The proposed solutions provide practical design and qualification guidelines for robust operation under frequent breakdown conditions.
Förderung
- EUROfusion Consortium through European Union via the Euratom Research and Training Program
- EUROfusion
- International Thermonuclear Experimental Reactor (ITER) Reversed Field eXperiment (RFX) Neutral Beam Testing Facility (NBTF) Agreement from the ITER Organizati…
Zitieren
APA
Dan, M., Casagrande, R., Bigi, M., Nardi, M. D., Fasolo, D., Maistrello, A., Patton, T., Recchia, M., Santoro, F., Baseggio, L., Zerbetto, E., & Zanotto, L. (2026). Design and Implementation of Fast Transient Overvoltage Protection Systems for SPIDER Power Supplies. IEEE Transactions on Plasma Science, 54(6), 2834-2841. https://doi.org/10.1109/tps.2026.3676325
Vancouver
Dan M, Casagrande R, Bigi M, Nardi MD, Fasolo D, Maistrello A, et al. Design and Implementation of Fast Transient Overvoltage Protection Systems for SPIDER Power Supplies. IEEE Transactions on Plasma Science. 2026;54(6):2834-2841. doi:10.1109/tps.2026.3676325
BibTeX
@article{Dan2026,
author = {Dan, Mattia and Casagrande, Riccardo and Bigi, Marco and Nardi, Marco De and Fasolo, Daniele and Maistrello, Alberto and Patton, Tommaso and Recchia, Mauro and Santoro, Francesco and Baseggio, Lucio and Zerbetto, Enrico and Zanotto, Loris},
title = {Design and Implementation of Fast Transient Overvoltage Protection Systems for SPIDER Power Supplies},
journal = {IEEE Transactions on Plasma Science},
year = {2026},
volume = {54},
number = {6},
pages = {2834--2841},
doi = {10.1109/tps.2026.3676325}
}