EUVIMEDEUVIMED entdecken
Crossref

Experimental Analysis of HV-Bipolar Impulse Modulator With Variable Parameters of DBD-Based Kr/Cl 2 Excilamps

Subhash Kumar Ram, Brijendra Kumar Verma, Priti Pal, Akhilesh Mishra, Udit Narayan Pal, Sukumar Mishra, Sachin Devassy

IEEE Transactions on Plasma Science · 2025-12 · 53 (12) · 3865-3873

DOI: 10.1109/tps.2025.3620012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Plasma Science, 2025-12. Verfasst von Subhash Kumar Ram und 6 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Department of Science and Technology (DST), Government of India.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The generation of uniform and stable plasma in the dielectric barrier discharge (DBD) based coaxial Kr/Cl2 excilamps requires the utilization of a matched high-voltage pulse power modulator. Variations in DBD plasma load parameters, such as pressure and electrode gap, directly affect the high-voltage pulse power modulator, leading to changes in breakdown voltage and waveform characteristics. The design of a high-voltage bipolar impulse modulator with a pulse repetition frequency of 31.5 kHz and pulsewidth of 1 $\mu $ s for DBD-based coaxial Kr/Cl2 excilamps has been carried out. The hardware laboratory prototype of a high-voltage bipolar impulse modulator has been realized using SiC-based semiconductor switching devices. The developed high-voltage bipolar impulse modulator has been experimentally characterized with various DBD-based 222 nm Kr/Cl2 excilamps. The developed high-voltage bipolar impulse modulator system is used to observe and analyze the emission spectra of various DBD-based coaxial Kr/Cl2 excilamps under different conditions of fixed and variable pressures and electrode gaps. Similarly, the applied bipolar voltage and intensity of various DBD-based coaxial Kr/Cl2 excilamp is measured and analyzed under both fixed and varying electrode gaps and pressures. The electrical-to-optical conversion efficiency is evaluated for all DBD tubes, with Tube 5 showing the highest efficiency of ~26% operating at a 7.5 mm gap and 300 mbar pressure. The pulse rise time of the output voltage with various DBD-based Kr/Cl2 excilamps is measured and analyzed. Twenty consecutive bipolar output pulses tested with excilamp, superimposed on each other, demonstrate stable operation of a high-voltage bipolar impulse modulator with negligible timing jitter.

Förderung

  • Department of Science and Technology (DST), Government of India

Zitieren

APA

Ram, S. K., Verma, B. K., Pal, P., Mishra, A., Pal, U. N., Mishra, S., & Devassy, S. (2025). Experimental Analysis of HV-Bipolar Impulse Modulator With Variable Parameters of DBD-Based Kr/Cl 2 Excilamps. IEEE Transactions on Plasma Science, 53(12), 3865-3873. https://doi.org/10.1109/tps.2025.3620012

Vancouver

Ram SK, Verma BK, Pal P, Mishra A, Pal UN, Mishra S, et al. Experimental Analysis of HV-Bipolar Impulse Modulator With Variable Parameters of DBD-Based Kr/Cl 2 Excilamps. IEEE Transactions on Plasma Science. 2025;53(12):3865-3873. doi:10.1109/tps.2025.3620012

BibTeX
@article{Ram2025,
  author = {Ram, Subhash Kumar and Verma, Brijendra Kumar and Pal, Priti and Mishra, Akhilesh and Pal, Udit Narayan and Mishra, Sukumar and Devassy, Sachin},
  title = {Experimental Analysis of HV-Bipolar Impulse Modulator With Variable Parameters of DBD-Based Kr/Cl 2 Excilamps},
  journal = {IEEE Transactions on Plasma Science},
  year = {2025},
  volume = {53},
  number = {12},
  pages = {3865--3873},
  doi = {10.1109/tps.2025.3620012}
}
Kostenlos starten →