Dynamic Analysis and Control Design to Mitigate Clamp Capacitor Voltage Ringing in Current Mode-Controlled Active Clamp Forward Converters
IEEE Transactions on Power Electronics · 2026-11 · 41 (11) · 19543-19556
DOI: 10.1109/tpel.2026.3701796 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Power Electronics, 2026-11. Verfasst von Dongheon Lee und 3 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Gefördert von: National Research Foundation of Korea, Korea government, Korea Institute of Energy Technology Evaluation and Planning.
Abstract (Originalsprache)
In an active clamp forward converter (ACFC), an oscillatory upsurge or ringing of the clamp capacitor voltage directly elevates the voltage stress of the main switch and the risk of saturating the isolation transformer. The magnitude of the voltage upsurge has been known to be largely affected by the loop gain characteristics of the converter. However, detailed analytical relations between them have not been fully revealed yet. Previous studies have addressed this issue via complex mathematical computations with limited engineering insights. This work demonstrates that the magnitude of the ringing is collectively influenced by both the 0 dB crossover frequency and the gain margin of the converter loop gain. The ringing could be alleviated when the loop gain crossover frequency is extended to a vicinity of the output filter double pole frequency, while retaining a sufficient gain margin. In some cases, a considerate design tradeoff is necessary between the crossover frequency and gain margin, in order to soften the oscillatory rise of the clamp capacitor voltage. Such a design guideline is proposed to reduce the voltage stress of main switch and danger of transformer saturation. The proposed design strategy is empirically verified with a 50 W experimental prototype ACFC, as well as extensive computer simulations.
Förderung
- National Research Foundation of Korea
- Korea government
- Korea Institute of Energy Technology Evaluation and Planning
- Ministry of Climate, Energy and Environment
- Republic of Korea
Zitieren
APA
Lee, D., Kang, Y., Choi, B., & Cha, H. (2026). Dynamic Analysis and Control Design to Mitigate Clamp Capacitor Voltage Ringing in Current Mode-Controlled Active Clamp Forward Converters. IEEE Transactions on Power Electronics, 41(11), 19543-19556. https://doi.org/10.1109/tpel.2026.3701796
Vancouver
Lee D, Kang Y, Choi B, Cha H. Dynamic Analysis and Control Design to Mitigate Clamp Capacitor Voltage Ringing in Current Mode-Controlled Active Clamp Forward Converters. IEEE Transactions on Power Electronics. 2026;41(11):19543-19556. doi:10.1109/tpel.2026.3701796
BibTeX
@article{Lee2026,
author = {Lee, Dongheon and Kang, Yonghan and Choi, Byungcho and Cha, Honnyong},
title = {Dynamic Analysis and Control Design to Mitigate Clamp Capacitor Voltage Ringing in Current Mode-Controlled Active Clamp Forward Converters},
journal = {IEEE Transactions on Power Electronics},
year = {2026},
volume = {41},
number = {11},
pages = {19543--19556},
doi = {10.1109/tpel.2026.3701796}
}