A Fault Diagnosis and Differentiated Processing Strategy for Grid Side Overcurrent Faults in Electric Traction Drive System

Qiang Ni, Jinxin Zhang, Canbing Li, Zhicheng Cai, Honghui Fang, Jie Tao

IEEE Transactions on Power Electronics · 2026-11 · 41 (11) · 19174-19184

DOI: 10.1109/tpel.2026.3701489 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Power Electronics, 2026-11. Verfasst von Qiang Ni und 5 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Natural Science Foundation of Guangdong Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Grid-side overcurrent (GSOC) in the traction transformer is a system-level fault in the electric traction drive system. Once it occurs, the traction control unit indiscriminately trips the main circuit breaker to ensure safety, causing the train to stop and requiring inspection and maintenance by the crew. This excessive protection and manual maintenance approach reduces the availability and operational efficiency of the trains. Therefore, this article proposes a fault diagnosis and differentiated processing strategy for GSOC. First, the GSOC mechanism and the degree of deterioration are analyzed, and the different types of GSOC are classified as permanent fault or temporary fault. Second, the effective segment of the fault signal is selected, and the fault temporal features are extracted. Third, the differentiated processing strategy is proposed based on the diagnostic results and the degree of fault deterioration. Finally, the fault diagnostic model is established based on random forest classifier, and then the fault scenario is reproduced on the RT-LAB and the diagnostic model is implemented using a digital signal processor to complete the verification experiments. The experimental results show that, compared with existing methods, the proposed method can not only achieve 100% diagnostic accuracy but also significantly shorten the diagnostic time. Moreover, the differentiated processing strategy can greatly reduce the trains’ stopping time and frequency caused by GSOC.

Förderung

  • Natural Science Foundation of Guangdong Province

Zitieren

APA

Ni, Q., Zhang, J., Li, C., Cai, Z., Fang, H., & Tao, J. (2026). A Fault Diagnosis and Differentiated Processing Strategy for Grid Side Overcurrent Faults in Electric Traction Drive System. IEEE Transactions on Power Electronics, 41(11), 19174-19184. https://doi.org/10.1109/tpel.2026.3701489

Vancouver

Ni Q, Zhang J, Li C, Cai Z, Fang H, Tao J. A Fault Diagnosis and Differentiated Processing Strategy for Grid Side Overcurrent Faults in Electric Traction Drive System. IEEE Transactions on Power Electronics. 2026;41(11):19174-19184. doi:10.1109/tpel.2026.3701489

BibTeX
@article{Ni2026,
  author = {Ni, Qiang and Zhang, Jinxin and Li, Canbing and Cai, Zhicheng and Fang, Honghui and Tao, Jie},
  title = {A Fault Diagnosis and Differentiated Processing Strategy for Grid Side Overcurrent Faults in Electric Traction Drive System},
  journal = {IEEE Transactions on Power Electronics},
  year = {2026},
  volume = {41},
  number = {11},
  pages = {19174--19184},
  doi = {10.1109/tpel.2026.3701489}
}
Kostenlos starten →