Transient Stability Analysis of Grid-Forming Converters With an Elliptical Current Limiter Under Asymmetrical Grid Faults
IEEE Transactions on Power Electronics · 2026-08 · 41 (8) · 12628-12633
DOI: 10.1109/tpel.2026.3674342 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Power Electronics, 2026-08. Verfasst von Seongyeon Kim und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 13 Literaturangaben. Gefördert von: Korea Institute of Energy Technology Evaluation and Planning, Ministry of Climate, Energy and Environment.
Abstract (Originalsprache)
Under asymmetrical faults, analyzing the transient stability of grid-forming voltage-source converters (GFM-VSCs) becomes essential because their behavior fundamentally differs from that under symmetrical faults. In particular, the point-of-common-coupling voltage of a GFM-VSC contains both positive- and negative-sequence components, and the interaction between these components generates a nonnegligible negative-sequence-driven active power. However, the transient stability of GFM-VSCs under asymmetrical faults has not been sufficiently investigated, and the influence of negative-sequence-driven active power remains unclear. Accordingly, this letter derives the $P$ – $\delta$ curve of a GFM-VSC with an elliptical current limiter under asymmetrical faults by explicitly accounting for negative-sequence effects. This enables a more accurate transient stability assessment when extending conventional symmetrical-fault analyses to asymmetrical conditions. The theoretical analysis is validated by the agreement between the derived $P$ – $\delta$ curve and both simulation and experimental results.
Förderung
- Korea Institute of Energy Technology Evaluation and Planning
- Ministry of Climate
- Energy and Environment
- Republic of Korea
Zitieren
APA
Kim, S., Kim, K., Cui, S., & Jung, J. (2026). Transient Stability Analysis of Grid-Forming Converters With an Elliptical Current Limiter Under Asymmetrical Grid Faults. IEEE Transactions on Power Electronics, 41(8), 12628-12633. https://doi.org/10.1109/tpel.2026.3674342
Vancouver
Kim S, Kim K, Cui S, Jung J. Transient Stability Analysis of Grid-Forming Converters With an Elliptical Current Limiter Under Asymmetrical Grid Faults. IEEE Transactions on Power Electronics. 2026;41(8):12628-12633. doi:10.1109/tpel.2026.3674342
BibTeX
@article{Kim2026,
author = {Kim, Seongyeon and Kim, Ki-Hyun and Cui, Shenghui and Jung, Jae-Jung},
title = {Transient Stability Analysis of Grid-Forming Converters With an Elliptical Current Limiter Under Asymmetrical Grid Faults},
journal = {IEEE Transactions on Power Electronics},
year = {2026},
volume = {41},
number = {8},
pages = {12628--12633},
doi = {10.1109/tpel.2026.3674342}
}
EUVIMED