EUVIMEDEUVIMED entdecken
Crossref

Accurate Interturn Short-Circuit Faults Diagnosis in PMSMs Under Variable Operating Conditions by Signal Compensation

Feng Niu, Mingge Xu, Feng Zhou, Shaopo Huang, Zijun Xu, Lu Zhang, Anmol Aggarwal

IEEE Transactions on Power Electronics · 2025-02 · 40 (2) · 3530-3542

DOI: 10.1109/tpel.2024.3487628 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Power Electronics, 2025-02. Verfasst von Feng Niu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Tianjin Municipality, Beijing Municipal Education Commission.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Interturn short-circuit (ITSC) is one of the most common faults in permanent magnet synchronous machines (PMSMs), but most ITSC diagnosis methods are only validated under steady operating conditions. In practice, the commanded speed or commanded torque of PMSM drive system need to be changed frequently to meet some special demands. When PMSMs run under variable operating conditions (especially transient operating conditions), the abrupt changes of speed or torque introduce extra harmonics in machine currents and voltages, which may lead to unexpected fault alarms and financial losses. This article establishes the dynamic response models of the current and voltage of closed-loop PMSM drive based on the system transfer functions, and the dynamic responses of the current and voltage under variable operating conditions can be obtained. Based on these models, an ITSC diagnosis method is proposed to compensate for the harmonic transient spikes in the current and voltage due to the abrupt changes in machine speed and load torque, thereby reducing the possibility of ITSC misdiagnosis. Experimental tests are carried out on a PMSM with ITSC to verify the proposed method, and the results show that the method can accurately detect ITSC faults and avoid fault misdiagnosis.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Tianjin Municipality
  • Beijing Municipal Education Commission

Zitieren

APA

Niu, F., Xu, M., Zhou, F., Huang, S., Xu, Z., Zhang, L., & Aggarwal, A. (2025). Accurate Interturn Short-Circuit Faults Diagnosis in PMSMs Under Variable Operating Conditions by Signal Compensation. IEEE Transactions on Power Electronics, 40(2), 3530-3542. https://doi.org/10.1109/tpel.2024.3487628

Vancouver

Niu F, Xu M, Zhou F, Huang S, Xu Z, Zhang L, et al. Accurate Interturn Short-Circuit Faults Diagnosis in PMSMs Under Variable Operating Conditions by Signal Compensation. IEEE Transactions on Power Electronics. 2025;40(2):3530-3542. doi:10.1109/tpel.2024.3487628

BibTeX
@article{Niu2025,
  author = {Niu, Feng and Xu, Mingge and Zhou, Feng and Huang, Shaopo and Xu, Zijun and Zhang, Lu and Aggarwal, Anmol},
  title = {Accurate Interturn Short-Circuit Faults Diagnosis in PMSMs Under Variable Operating Conditions by Signal Compensation},
  journal = {IEEE Transactions on Power Electronics},
  year = {2025},
  volume = {40},
  number = {2},
  pages = {3530--3542},
  doi = {10.1109/tpel.2024.3487628}
}
Kostenlos starten →