EUVIMEDEUVIMED entdecken
Crossref

A Fault Tolerant Modulation Scheme for a Hybrid Multilevel Inverter in the Event of Open-Switch Fault

Richa Goel, Dheeraj Etta, Ravi Varma Chavali, Anubrata Dey

IEEE Transactions on Power Electronics · 2025-03 · 40 (3) · 3861-3872

DOI: 10.1109/tpel.2024.3486006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Power Electronics, 2025-03. Verfasst von Richa Goel und 3 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Science and Engineering Research Board, GoI.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With ever-increasing renewable power penetration, the reliable operation of grid interfaced inverter is an important criterion. The availability of a grid-connected multilevel inverter is relied upon the correctness of identifying faulty switch, if any, during operation and implementation of a fault-tolerant modulation technique to run the inverter without tripping off even under faulty conditions. Although having a large number of switches in a multilevel inverter throws challenges for the detection and localization of faults, it is a boon because power can still flow through alternative paths. In pursuit of this objective, this paper utilizes a T-type based hybrid multilevel topology where certain faulty conditions are created. The proposed fault detection scheme begins with the fast identification of faulty phase, achieved by monitoring the absolute phase error variable derived from normalized phase currents. Subsequently, the localization of faulty switch is fulfilled by intricate analysis of several current and voltage measurements. Notably, the proposed scheme does not need additional sensors to carry out all of these, where finally, a carrier-based fault tolerant scheme is devised to encounter open switch faults. The effectiveness and feasibility of the proposed scheme are evaluated by simulation studies followed by experiments on a seven-level inverter prototype.

Förderung

  • Science and Engineering Research Board, GoI

Zitieren

APA

Goel, R., Etta, D., Chavali, R. V., & Dey, A. (2025). A Fault Tolerant Modulation Scheme for a Hybrid Multilevel Inverter in the Event of Open-Switch Fault. IEEE Transactions on Power Electronics, 40(3), 3861-3872. https://doi.org/10.1109/tpel.2024.3486006

Vancouver

Goel R, Etta D, Chavali RV, Dey A. A Fault Tolerant Modulation Scheme for a Hybrid Multilevel Inverter in the Event of Open-Switch Fault. IEEE Transactions on Power Electronics. 2025;40(3):3861-3872. doi:10.1109/tpel.2024.3486006

BibTeX
@article{Goel2025,
  author = {Goel, Richa and Etta, Dheeraj and Chavali, Ravi Varma and Dey, Anubrata},
  title = {A Fault Tolerant Modulation Scheme for a Hybrid Multilevel Inverter in the Event of Open-Switch Fault},
  journal = {IEEE Transactions on Power Electronics},
  year = {2025},
  volume = {40},
  number = {3},
  pages = {3861--3872},
  doi = {10.1109/tpel.2024.3486006}
}
Kostenlos starten →