A Radiation-Hardened Ramp ADC With Self-Calibrating Slope for High-Dose Applications
IEEE Transactions on Nuclear Science · 2026-08 · 73 (8) · 3481-3492
DOI: 10.1109/tns.2026.3710340 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Nuclear Science, 2026-08. Verfasst von Pengxu Li und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: School of Physics, Zhejiang University, China Institute of Atomic Energy.
Abstract (Originalsprache)
This article presents an 11-bit, 64-channel slope-self-calibrated ramp (SSCR) analog-to-digital converter (ADC) fabricated in a 180 nm CMOS process for reliable operation in nuclear reactor monitoring systems. To address the vulnerability of conventional ramp ADCs to process, voltage, and temperature (PVT) variations as well as total ionizing dose (TID) effects, a successive approximation register (SAR)-based self-calibration loop is proposed. This architecture detects conversion slope errors and compensates for them by adjusting the charging current. In addition, enclosed layout transistors (ELTs), guard rings, and an input-swapping mechanism are implemented to enhance radiation tolerance and inter-channel uniformity. Measured results demonstrate that the self-calibration technique effectively suppresses slope variations. Under comprehensive PVT conditions spanning seven samples, a temperature range of −40 $\mathrm {{^{\circ}C}}$ to 125 $\mathrm {{^{\circ}C}}$ , and ±50 mV supply variations, the maximum slope error is reduced from 15% to less than 1.1%. During X-ray irradiation up to 200 Mrad(SiO 2 ), the ADC samples exhibit temporary performance degradation at around 5 Mrad(SiO 2 ), with the signal-to-noise ratio (SNR) decreasing to 54 dB, the differential nonlinearity (DNL) increasing to 0.47 LSB, and the integral nonlinearity (INL) increasing to 3.4 LSB. However, at the target dose of 200 Mrad(SiO 2 ), the performance recovers, achieving a DNL of 0.18 LSB, an INL of 0.86 LSB, and an SNR of 60 dB. This recovered performance remains stable during a subsequent 168-h high-temperature annealing process at 100 $\mathrm {{^{\circ}C}}$ .
Förderung
- School of Physics, Zhejiang University
- China Institute of Atomic Energy
Zitieren
APA
Li, P., Geng, X., Wang, S., Ye, Z., Xiao, M., & Zhu, H. (2026). A Radiation-Hardened Ramp ADC With Self-Calibrating Slope for High-Dose Applications. IEEE Transactions on Nuclear Science, 73(8), 3481-3492. https://doi.org/10.1109/tns.2026.3710340
Vancouver
Li P, Geng X, Wang S, Ye Z, Xiao M, Zhu H. A Radiation-Hardened Ramp ADC With Self-Calibrating Slope for High-Dose Applications. IEEE Transactions on Nuclear Science. 2026;73(8):3481-3492. doi:10.1109/tns.2026.3710340
BibTeX
@article{Li2026,
author = {Li, Pengxu and Geng, Xin and Wang, Shuangyuan and Ye, Zhiyong and Xiao, Meng and Zhu, Hongbo},
title = {A Radiation-Hardened Ramp ADC With Self-Calibrating Slope for High-Dose Applications},
journal = {IEEE Transactions on Nuclear Science},
year = {2026},
volume = {73},
number = {8},
pages = {3481--3492},
doi = {10.1109/tns.2026.3710340}
}
EUVIMED