EUVIMEDEUVIMED entdecken
Crossref

Pointing Calibration Study for the HADAR Experiment

Huiying Sun, Xiangli Qian, Tianlu Chen, Maoyuan Liu, Cheng Liu, Youliang Feng

IEEE Transactions on Nuclear Science · 2026-07 · 73 (7) · 2618-2628

DOI: 10.1109/tns.2026.3701130 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Nuclear Science, 2026-07. Verfasst von Huiying Sun und 5 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Projects of Xizang Autonomous Region, open research fund of the Key Laboratory of Cosmic Rays (Xizang University), Ministry of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

HADAR is an ultra-wide-angle atmospheric Cherenkov telescope that employs a water-lens optical system, offering significant advantages in detecting gamma-ray sources, including bursts, transients, and extended sources. Given its implementation of an innovative transmissive optical technology, the precise pointing accuracy of both the telescope and imaging system is critical, as it directly influences the reconstruction accuracy of gamma-ray events based on Cherenkov light detection. Consequently, rigorous calibration is essential. In this study, we present a calibration method to determine the optical axis orientation of the HADAR imaging system. This method leverages the distinct signal variations observed in the imaging system’s pixel units when bright stars transit through the field of view of the water lens, thereby enabling the precise calibration of the telescope’s geometric properties. Applying this method to the 0.9-m HADAR prototype system, we analyzed the imaging characteristics induced by bright stars and performed an accurate calibration of the prototype’s imaging system alignment. Our results confirm the effectiveness of this calibration approach. This technique will be further employed for the alignment and calibration of future large-aperture water-lens telescopes in the HADAR experiment.

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Projects of Xizang Autonomous Region
  • open research fund of the Key Laboratory of Cosmic Rays (Xizang University), Ministry of Education

Zitieren

APA

Sun, H., Qian, X., Chen, T., Liu, M., Liu, C., & Feng, Y. (2026). Pointing Calibration Study for the HADAR Experiment. IEEE Transactions on Nuclear Science, 73(7), 2618-2628. https://doi.org/10.1109/tns.2026.3701130

Vancouver

Sun H, Qian X, Chen T, Liu M, Liu C, Feng Y. Pointing Calibration Study for the HADAR Experiment. IEEE Transactions on Nuclear Science. 2026;73(7):2618-2628. doi:10.1109/tns.2026.3701130

BibTeX
@article{Sun2026,
  author = {Sun, Huiying and Qian, Xiangli and Chen, Tianlu and Liu, Maoyuan and Liu, Cheng and Feng, Youliang},
  title = {Pointing Calibration Study for the HADAR Experiment},
  journal = {IEEE Transactions on Nuclear Science},
  year = {2026},
  volume = {73},
  number = {7},
  pages = {2618--2628},
  doi = {10.1109/tns.2026.3701130}
}
Kostenlos starten →