EUVIMEDEUVIMED entdecken
Crossref

Design and Performance Evaluation of a Filter-Free Dual-Layer Flat-Panel Detector Using Monte Carlo Simulation

Jiyong Shim, Bo Kyung Cha, Hyosung Cho

IEEE Transactions on Nuclear Science · 2026-05 · 73 (5) · 1681-1688

DOI: 10.1109/tns.2026.3678415 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Nuclear Science, 2026-05. Verfasst von Jiyong Shim und 2 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry, and Energy (MOTIE), Republic of Korea.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study proposes and evaluates a filter-free dual-layer flat-panel detector (DL-FPD) using Monte Carlo simulations based on the Geant4 toolkit. The design removes the conventional copper (Cu) interlayer filter and increases the thickness of the top scintillator to achieve spectral separation without a Cu interlayer. The objective is to determine whether eliminating the interlayer filter can improve photon utilization while preserving dual-energy imaging performance across diagnostic beam qualities. Simulation results show that removal of the Cu interlayer increases photon fluence in the bottom detector layer compared with the conventional DL-FPD configuration. The increased photon utilization is reflected in key image quality metrics, including spatial resolution and noise characteristics. Under RQA5 and RQA7 beam qualities, noise-equivalent quanta (NEQ) increase in both detector layers, whereas beam-dependent variations are observed under RQA9. Dual-energy material decomposition (DEMD) using polymethyl methacrylate (PMMA)–Al wedge phantoms demonstrates modest contrast-to-noise ratio (CNR) improvement in PMMA images and beam-quality-dependent changes in Al images. In particular, Al contrast shows notable relative improvement under RQA5 and RQA7, while differences are marginal under RQA9. Overall, the proposed DL-FPD configuration provides comparable dual-energy imaging performance with improved photon utilization and increased bottom-layer NEQ. These findings demonstrate that removing the interlayer filter can improve photon statistics while maintaining practical dual-energy imaging performance.

Förderung

  • Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry, and Energy (MOTIE), Republic of Korea

Zitieren

APA

Shim, J., Cha, B. K., & Cho, H. (2026). Design and Performance Evaluation of a Filter-Free Dual-Layer Flat-Panel Detector Using Monte Carlo Simulation. IEEE Transactions on Nuclear Science, 73(5), 1681-1688. https://doi.org/10.1109/tns.2026.3678415

Vancouver

Shim J, Cha BK, Cho H. Design and Performance Evaluation of a Filter-Free Dual-Layer Flat-Panel Detector Using Monte Carlo Simulation. IEEE Transactions on Nuclear Science. 2026;73(5):1681-1688. doi:10.1109/tns.2026.3678415

BibTeX
@article{Shim2026,
  author = {Shim, Jiyong and Cha, Bo Kyung and Cho, Hyosung},
  title = {Design and Performance Evaluation of a Filter-Free Dual-Layer Flat-Panel Detector Using Monte Carlo Simulation},
  journal = {IEEE Transactions on Nuclear Science},
  year = {2026},
  volume = {73},
  number = {5},
  pages = {1681--1688},
  doi = {10.1109/tns.2026.3678415}
}
Kostenlos starten →