EUVIMEDEUVIMED entdecken
Crossref

Machine Learning-Based Accurate Analysis of cTnI With Alphalisa Immunoassay Enabled Centrifugal Microfluidic System

Yuxing Shi, Chuang Wang, Bochen Xiong, Yiqiang Hou, Peng Ye, Jinhong Guo

IEEE Transactions on NanoBioscience · 2023

DOI: 10.1109/tnb.2022.3224484 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on NanoBioscience, 2023. Verfasst von Yuxing Shi und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Troponin I, Myocardial Infarction. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac troponin (cTnI) is a biomarker with high sensitivity and specificity for acute myocardial infarction (AMI). Rapid and accurate detection of cTnI can effectively reduce the mortality of AMI. Aiming at the problems of complex operation and low sensitivity of traditional methods used to detect cTnI, an Alphalisa immunoassay enabled centrifugal microfluidic system (AIECMS) is designed to detect cTnI quickly with high sensitivity, and good accuracy is achieved in the linear range of 0.1 ng/mL-50 ng/mL. However, in order to realize the detection of hypersensitive cTnI (the definition standard of weak positive and negative is 0.08 ng/mL), it is necessary to further improve the accuracy of qualitative detection. Since the signal curve of the system for reagents of low concentration range is relatively close, the system can not accurately distinguish weak positive and negative samples, which is easy to cause misjudgment of detection results. In order to solve this problem, this paper proposes to apply machine learning to the signal processing detected by AIECMS for the first time. Firstly, different pre-processing is done according to the characteristics of biological signals; Secondly, different machine learning algorithms are used to train and test the data, and the classification of four clinically significant concentrations (0.02 ng/mL, 0.04 ng/mL, 0.08 ng/mL and 0.1 ng/mL) is realized. Finally, combining the performance of various algorithms, algorithm cost and clinical requirements for the accuracy of low concentration classification, we choose random forest (accuracy 92%) to accurately distinguish the weak positive and negative samples of cTnI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin IMyocardial InfarctionHumansMicrofluidicsBiomarkersImmunoassay

Substanzen

Troponin IBiomarkers

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Shi, Y., Wang, C., Xiong, B., Hou, Y., Ye, P., & Guo, J. (2023). Machine Learning-Based Accurate Analysis of cTnI With Alphalisa Immunoassay Enabled Centrifugal Microfluidic System. IEEE Transactions on NanoBioscience. https://doi.org/10.1109/tnb.2022.3224484

Vancouver

Shi Y, Wang C, Xiong B, Hou Y, Ye P, Guo J. Machine Learning-Based Accurate Analysis of cTnI With Alphalisa Immunoassay Enabled Centrifugal Microfluidic System. IEEE Transactions on NanoBioscience. 2023. doi:10.1109/tnb.2022.3224484

BibTeX
@article{Shi2023,
  author = {Shi, Yuxing and Wang, Chuang and Xiong, Bochen and Hou, Yiqiang and Ye, Peng and Guo, Jinhong},
  title = {Machine Learning-Based Accurate Analysis of cTnI With Alphalisa Immunoassay Enabled Centrifugal Microfluidic System},
  journal = {IEEE Transactions on NanoBioscience},
  year = {2023},
  doi = {10.1109/tnb.2022.3224484}
}
Kostenlos starten →