EUVIMEDEUVIMED entdecken
Crossref

28-nm Cryo-CMOS Mixer-First Reflectometer for the FDM Readout of Transmon Qubits

Yujie Geng, Zizhen Xu, Tianyu Dong, Yijie Chen, Weichen Wang, Yue Yang, Zhixiao Sun, Ruihong Wu, Haichuan Lin, Mingtang Deng, Cheng Wang

IEEE Transactions on Microwave Theory and Techniques · 2026-09 · 74 (9) · 8403-8416

DOI: 10.1109/tmtt.2026.3712115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Microwave Theory and Techniques, 2026-09. Verfasst von Yujie Geng und 10 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantum error correction (QEC) is in demand for a fault-tolerant quantum computer. Currently, the QEC cycle is bottlenecked by the quantum bit (qubit) readout. To this end, RF dispersive reflectometry with frequency division multiplexing (FDM) is preferred due to its high fidelity and scalability. However, for a low noise temperature $T_{noise}$ , cryogenic low noise amplifiers (cryo-LNAs) of classic LNA-first reflectometers require high transconductance efficiency ( $g_{m}^{2}/I_{d}$ ). These open-loop cryo-LNAs also present limited linearity under large output voltage, resulting in errors of FDM readout. In this work, a new approach, a mixer-first cryogenic CMOS (Cryo-CMOS) reflectometer, is explored for its potential advantages in noise and linearity. A passive, low-loss mixer directly down-converts the RF reflection from the qubits (5.5–8 GHz) at 4 K to IF/baseband (5–250 MHz). Then, an IF/baseband amplifier, employing a MOSFET pair of $W/L = 2{\,}\times {\,}800~\mu $ m/100 nm and current density of $5~\mu $ A/ $\mu $ m, achieves $2.8\times $ higher $g_{m}^{2}/I_{d}$ than Cryo-CMOS LNAs for low noise. After closed-loop amplification with high linearity, the baseband is sampled by a 500 MSPS, 12-bit time-interleaved (TI) analog-to-digital converter (ADC). Finally, the qubit state is discriminated by an on-chip FDM demodulation algorithm. Fabricated by a 28-nm bulk CMOS process, the mixer-first reflectometer at 4 K achieves a minimum $T_{noise} =19$ K at $f_{LO} =7.3$ GHz with a 42-dB RX gain, which is highly competitive to other LNA-first reflectometers. In addition, thanks to the co-optimization of single-sideband (SSB) transmitter (TX), mixer-first RX and on-chip demodulation, under a baseband amplitude of $V_{pp}\sim 0.8$ V, excellent spur-free dynamic range (SFDR) of SFDR > 45 dB and third-order intermodulation rejection of IMD $3\gt 50$ dB are recorded. Lastly, the simultaneous FDM readout of two transmon qubits has also been demonstrated with fidelity 95.3% and 92.3% for qubit1 states $|0\rangle {\,}\& {\,}|1\rangle $ , and fidelity 96.1% and 93.1% for qubit2 states $|0\rangle {\,}\& {\,}|1\rangle $ , respectively.

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Project

Zitieren

APA

Geng, Y., Xu, Z., Dong, T., Chen, Y., Wang, W., Yang, Y., Sun, Z., Wu, R., Lin, H., Deng, M., & Wang, C. (2026). 28-nm Cryo-CMOS Mixer-First Reflectometer for the FDM Readout of Transmon Qubits. IEEE Transactions on Microwave Theory and Techniques, 74(9), 8403-8416. https://doi.org/10.1109/tmtt.2026.3712115

Vancouver

Geng Y, Xu Z, Dong T, Chen Y, Wang W, Yang Y, et al. 28-nm Cryo-CMOS Mixer-First Reflectometer for the FDM Readout of Transmon Qubits. IEEE Transactions on Microwave Theory and Techniques. 2026;74(9):8403-8416. doi:10.1109/tmtt.2026.3712115

BibTeX
@article{Geng2026,
  author = {Geng, Yujie and Xu, Zizhen and Dong, Tianyu and Chen, Yijie and Wang, Weichen and Yang, Yue and Sun, Zhixiao and Wu, Ruihong and Lin, Haichuan and Deng, Mingtang and Wang, Cheng},
  title = {28-nm Cryo-CMOS Mixer-First Reflectometer for the FDM Readout of Transmon Qubits},
  journal = {IEEE Transactions on Microwave Theory and Techniques},
  year = {2026},
  volume = {74},
  number = {9},
  pages = {8403--8416},
  doi = {10.1109/tmtt.2026.3712115}
}
Kostenlos starten →