Fachartikel in der Zeitschrift IEEE Transactions on Microwave Theory and Techniques, 2026-02. Verfasst von Li Wen und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Shanghai Jiao Tong University Medical-Engineering Interdisciplinary Research Fund, Shanghai Science and Technology Funds.
Abstract (Originalsprache)
In long-term clinical monitoring, random body movements or clutter from nearby objects introduce time-varying dc offsets in the microwave biomedical radar system. The conventional dc offset calibration methods based on least-square (LS) circle fitting are ineffective for weak cardiopulmonary motions with low signal-to-noise ratio (SNR). To address the challenge, this article proposes a novel dc offset calibration technique that enables joint circle fitting of multiple segmented radar signal traces under approximately uniform maximum amplitude modulation. The proposed technique preserves amplitude and phase relationships through geometric space transformation, adaptively processes noise via a dual-mode fitting mechanism for dc offset calibration, and enhances robustness by integrating Huber loss residual computation with threshold-based optimization and averaged positioning. Validated across simulations and experiments in both lab and clinical environments, the proposed technique reduces demodulation errors by 10– $1000\times $ (for a $0.004\lambda $ displacement) compared to conventional LS single-segment circle fitting under comparable SNR conditions. It helps to tackle the imperfections of dc offsets in the microwave biomedical radar system, thus allowing microwave cardiogram-electrocardiogram feature alignment in arrhythmia patients and advancing radar-based long-term arrhythmia monitoring. The demonstrated mechanical-electrical correlation supports early risk prediction.
Förderung
- National Key Research and Development Program of China
- Shanghai Jiao Tong University Medical-Engineering Interdisciplinary Research Fund
- Shanghai Science and Technology Funds
- National Natural Science Foundation of China
Zitieren
APA
Wen, L., Cao, J., Guo, Y., Zeng, Z., Cao, Q., Chen, K., & Gu, C. (2026). Robust and Adaptive DC Offset Calibration in Microwave Sensing Systems for Long-Term Microwave Cardiogram Detection. IEEE Transactions on Microwave Theory and Techniques, 74(2), 1756-1769. https://doi.org/10.1109/tmtt.2025.3629611
Vancouver
Wen L, Cao J, Guo Y, Zeng Z, Cao Q, Chen K, et al. Robust and Adaptive DC Offset Calibration in Microwave Sensing Systems for Long-Term Microwave Cardiogram Detection. IEEE Transactions on Microwave Theory and Techniques. 2026;74(2):1756-1769. doi:10.1109/tmtt.2025.3629611
BibTeX
@article{Wen2026,
author = {Wen, Li and Cao, Jie and Guo, Yijing and Zeng, Zi and Cao, Qing and Chen, Kang and Gu, Changzhan},
title = {Robust and Adaptive DC Offset Calibration in Microwave Sensing Systems for Long-Term Microwave Cardiogram Detection},
journal = {IEEE Transactions on Microwave Theory and Techniques},
year = {2026},
volume = {74},
number = {2},
pages = {1756--1769},
doi = {10.1109/tmtt.2025.3629611}
}
EUVIMED