EUVIMEDEUVIMED entdecken
Crossref

An FFT-Based DC Offset Compensation and I/Q Imbalance Correction Algorithm for Bioradar Sensors

Fuze Tian, Lixian Zhu, Qiuxia Shi, Xiaokun Jin, Ran Cai, Qunxi Dong, Qinglin Zhao, Bin Hu

IEEE Transactions on Microwave Theory and Techniques · 2024-03 · 72 (3) · 1900-1910

DOI: 10.1109/tmtt.2023.3308190 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Microwave Theory and Techniques, 2024-03. Verfasst von Fuze Tian und 7 weiteren Autor:innen. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Ministry of Science and Technology, China, through the STI2030-Major Projects, National Key Research and Development Program of China, China Postdoctoral Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The challenge of noncontact presentation of human cardiopulmonary activity using a bioradar sensor is to linearly demodulate the Doppler cardiopulmonary diagram (DCD) signal from baseband signals. Arctangent demodulation can perform linear phase demodulation to obtain the DCD signal. However, the high-order harmonics and intermodulation terms (ITs) caused by the time-varying direct current (dc) offset and in-phase and quadrature-phase (I/Q) imbalance in the baseband signals significantly degrade the signal-to-noise ratio (SNR) of the Doppler heartbeat diagram (DHD) signal. In this work, a fast Fourier transform (FFT)-based algorithm is proposed to simultaneously perform time-varying dc offset compensation and I/Q imbalance correction without the need for an auxiliary device to improve the accuracy of the arctangent demodulation. The obtained results show that the SNRs of the algorithm-processed DHD signals are increased from 30.08 ± 2.41 to 68.88 ± 10.57 dB. In addition, the root mean square errors (RMSEs) of the C-C intervals of the DHD signals for eight subjects with respect to the J-J intervals of the ballistocardiogram (BCG) signals are 17.79 ± 2.72 ms (2.80% ± 0.43%), suggesting a promising potential of the DHD signal for noncontact biomedical applications.

Förderung

  • Ministry of Science and Technology, China, through the STI2030-Major Projects
  • National Key Research and Development Program of China
  • China Postdoctoral Science Foundation
  • National Natural Science Foundation of China
  • Beijing Institute of Technology (BIT) Research and Innovation Promoting Project
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Tian, F., Zhu, L., Shi, Q., Jin, X., Cai, R., Dong, Q., Zhao, Q., & Hu, B. (2024). An FFT-Based DC Offset Compensation and I/Q Imbalance Correction Algorithm for Bioradar Sensors. IEEE Transactions on Microwave Theory and Techniques, 72(3), 1900-1910. https://doi.org/10.1109/tmtt.2023.3308190

Vancouver

Tian F, Zhu L, Shi Q, Jin X, Cai R, Dong Q, et al. An FFT-Based DC Offset Compensation and I/Q Imbalance Correction Algorithm for Bioradar Sensors. IEEE Transactions on Microwave Theory and Techniques. 2024;72(3):1900-1910. doi:10.1109/tmtt.2023.3308190

BibTeX
@article{Tian2024,
  author = {Tian, Fuze and Zhu, Lixian and Shi, Qiuxia and Jin, Xiaokun and Cai, Ran and Dong, Qunxi and Zhao, Qinglin and Hu, Bin},
  title = {An FFT-Based DC Offset Compensation and I/Q Imbalance Correction Algorithm for Bioradar Sensors},
  journal = {IEEE Transactions on Microwave Theory and Techniques},
  year = {2024},
  volume = {72},
  number = {3},
  pages = {1900--1910},
  doi = {10.1109/tmtt.2023.3308190}
}