EUVIMEDEUVIMED entdecken
Crossref

An Advanced Calibration Method for Probe Leakage Correction in On-Wafer Test Systems

Yibang Wang, Xingchang Fu, Aihua Wu, Ye Huo, Chen Liu, Peng Luan, Lihua Lei, Faguo Liang, Chong Li

IEEE Transactions on Microwave Theory and Techniques · 2023-02 · 71 (2) · 682-690

DOI: 10.1109/tmtt.2022.3200050 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Microwave Theory and Techniques, 2023-02. Verfasst von Yibang Wang und 8 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: U.K. EPSRC.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents an advanced calibration method for solving the error terms due to probe-probe leakage in an on-wafer test system. A new 12-term error model for the on-wafer test system including vector network analyzer (VNA), frequency extenders, cables/waveguides, probes, probe contact pads and probe-probe leakage is introduced. A two-step calibration process and an algorithm with four on-chip calibration standards including one undefined Thru, two pairs of undefined symmetrical Reflects such as Open-Open and Short-Short pairs, and a pair of known Match loads has been developed. In addition, an improved circuit model for the Match load is proposed for enhanced accuracy. The calibration method has been tested on a mismatched attenuator for the frequency range between 0.2 and 110 GHz, and the results are compared with numerical simulation and existing calibration methods. It is shown that the attenuator’s $\vert S_{11}\vert $ is more consecutive and $\vert S_{21}\vert $ has been improved by up-to 1.7 dB. It is evident that the proposed calibration method has a simpler calibration process and less stringent requirements on calibration standards which are key for on-wafer system calibration at millimeter-wave and terahertz frequencies. More importantly, the new calibration method is more suitable for measurements in which DUTs have variable lengths.

Förderung

  • U.K. EPSRC

Zitieren

APA

Wang, Y., Fu, X., Wu, A., Huo, Y., Liu, C., Luan, P., Lei, L., Liang, F., & Li, C. (2023). An Advanced Calibration Method for Probe Leakage Correction in On-Wafer Test Systems. IEEE Transactions on Microwave Theory and Techniques, 71(2), 682-690. https://doi.org/10.1109/tmtt.2022.3200050

Vancouver

Wang Y, Fu X, Wu A, Huo Y, Liu C, Luan P, et al. An Advanced Calibration Method for Probe Leakage Correction in On-Wafer Test Systems. IEEE Transactions on Microwave Theory and Techniques. 2023;71(2):682-690. doi:10.1109/tmtt.2022.3200050

BibTeX
@article{Wang2023,
  author = {Wang, Yibang and Fu, Xingchang and Wu, Aihua and Huo, Ye and Liu, Chen and Luan, Peng and Lei, Lihua and Liang, Faguo and Li, Chong},
  title = {An Advanced Calibration Method for Probe Leakage Correction in On-Wafer Test Systems},
  journal = {IEEE Transactions on Microwave Theory and Techniques},
  year = {2023},
  volume = {71},
  number = {2},
  pages = {682--690},
  doi = {10.1109/tmtt.2022.3200050}
}