Remote Catheter System With Enhanced Haptic Feedback for Use in Endovascular Procedures
IEEE Transactions on Medical Robotics and Bionics · 2026-08 · 8 (3) · 1428-1437
DOI: 10.1109/tmrb.2026.3713994 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Robotics and Bionics, 2026-08. Verfasst von Takenori Akiyama und 8 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
We propose a sensorless remote catheter control system that delivers real-time haptic feedback. Bilateral control combined with a reaction force observer estimates contact forces and transmits them to the operator in real time, while frequency-shaped feedback improves the perceived sensitivity and reduces fatigue. Using three catheter types and three operators, we evaluated position–force synchronization, loop delay, and vessel-wall load relative to manual manipulation. The average position error was approximately $2.14\times 10^{-5}{\,}\mathrm {m}$ , and the force error was $0.493{\,}\mathrm {N}$ . Cross-correlation ( $\leq 1{\,}\mathrm {Hz}$ ) showed no measurable lag in the low-frequency synchronization analysis within the 1 ms resolution. For force equivalence, the prespecified primary analysis employed a two one-sided tests (TOST) procedure based on estimates obtained from a linear mixed-effects (LME) model, with the smallest effect size set to ±10% of the manual mean; equivalence was supported (b $= -0.029$ , 90% confidence interval [−0.119, 0.061]), whereas a stricter ±5% sensitivity analysis was not supported. All operators completed the tasks after minimal system familiarization. These findings indicate that the system replicates manual precision in a benchtop phantom setting while enabling real-time haptic feedback and maintaining vessel-wall loading comparable to that of manual manipulation. Our sensorless haptic technology represents a promising step toward future clinical translation of remote catheter systems, with applications in safer, standardized, and more intuitive endovascular procedures.
Zitieren
APA
Akiyama, T., Kitamura, T., Nogawa, H., Iwama, T., Saito, Y., Asai, H., Shibao, S., Mizutani, K., & Ohnishi, K. (2026). Remote Catheter System With Enhanced Haptic Feedback for Use in Endovascular Procedures. IEEE Transactions on Medical Robotics and Bionics, 8(3), 1428-1437. https://doi.org/10.1109/tmrb.2026.3713994
Vancouver
Akiyama T, Kitamura T, Nogawa H, Iwama T, Saito Y, Asai H, et al. Remote Catheter System With Enhanced Haptic Feedback for Use in Endovascular Procedures. IEEE Transactions on Medical Robotics and Bionics. 2026;8(3):1428-1437. doi:10.1109/tmrb.2026.3713994
BibTeX
@article{Akiyama2026,
author = {Akiyama, Takenori and Kitamura, Tomoya and Nogawa, Hirotsugu and Iwama, Takashi and Saito, Yuki and Asai, Hiroshi and Shibao, Shunsuke and Mizutani, Katsuhiro and Ohnishi, Kouhei},
title = {Remote Catheter System With Enhanced Haptic Feedback for Use in Endovascular Procedures},
journal = {IEEE Transactions on Medical Robotics and Bionics},
year = {2026},
volume = {8},
number = {3},
pages = {1428--1437},
doi = {10.1109/tmrb.2026.3713994}
}
EUVIMED