EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Off-Axis Compliant RCM Joint With Near-Isotropic Stiffness and Minimal Parasitic Error

Federico Mariano, Elena De Momi, Giovanni Berselli, Jovana Jovanova, Just L. Herder, Leonardo S. Mattos

IEEE Transactions on Medical Robotics and Bionics · 2026-08 · 8 (3) · 1264-1275

DOI: 10.1109/tmrb.2026.3712832 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Robotics and Bionics, 2026-08. Verfasst von Federico Mariano und 5 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents an off-axis, monolithic compliant Remote Center of Motion (RCM) joint for neuroendoscopic manipulation, combining near-isotropic stiffness with minimal parasitic motion. Based on the Tetra II concept, the end-effector is placed outside the tetrahedral flexure to improve line of sight, facilitate sterilization, and allow rapid tool release. Design proceeds in two stages: mobility panels are sized with a compliance-based isotropy objective, then constraining panels are synthesized through finite-element feasibility exploration to trade stiffness isotropy against RCM drift. The joint is modeled with beam elements and validated via detailed finite-element analyses, including fatigue-bounded stress constraints. A PA12 prototype is fabricated by selective laser sintering and characterized on a benchtop: a 2 N radial load is applied at the end-effector while a 6-DOF electromagnetic sensor records pose. The selected configuration produces a stiffness-ellipse principal axis ratio (PAR) of 1.37 and a parasitic-to-useful rotation ratio (PRR) of 0.63%. Under a 4.5° commanded rotation, the predicted RCM drift remains sub-millimetric ( $0.015-0.172$ mm). Fatigue analysis predicts a usable rotational workspace of $12.1^{\circ } -34.4^{\circ } $ depending on direction. Experiments reproduce the simulated directional stiffness trend with typical deviations of $6-30\%$ , demonstrating a compact, fabrication-ready RCM module for constrained surgical access.

Zitieren

APA

Mariano, F., Momi, E. D., Berselli, G., Jovanova, J., Herder, J. L., & Mattos, L. S. (2026). Off-Axis Compliant RCM Joint With Near-Isotropic Stiffness and Minimal Parasitic Error. IEEE Transactions on Medical Robotics and Bionics, 8(3), 1264-1275. https://doi.org/10.1109/tmrb.2026.3712832

Vancouver

Mariano F, Momi ED, Berselli G, Jovanova J, Herder JL, Mattos LS. Off-Axis Compliant RCM Joint With Near-Isotropic Stiffness and Minimal Parasitic Error. IEEE Transactions on Medical Robotics and Bionics. 2026;8(3):1264-1275. doi:10.1109/tmrb.2026.3712832

BibTeX
@article{Mariano2026,
  author = {Mariano, Federico and Momi, Elena De and Berselli, Giovanni and Jovanova, Jovana and Herder, Just L. and Mattos, Leonardo S.},
  title = {Off-Axis Compliant RCM Joint With Near-Isotropic Stiffness and Minimal Parasitic Error},
  journal = {IEEE Transactions on Medical Robotics and Bionics},
  year = {2026},
  volume = {8},
  number = {3},
  pages = {1264--1275},
  doi = {10.1109/tmrb.2026.3712832}
}