Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair

Anna Bicchi, Xiu Zhang, Benjamín Ignacio Fortuño Jara, Vanessa Cannizzaro, Angela Peloso, Elena De Momi

IEEE Transactions on Medical Robotics and Bionics · 2025-05 · 7 (2) · 562-571

DOI: 10.1109/tmrb.2025.3550674 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Robotics and Bionics, 2025-05. Verfasst von Anna Bicchi und 5 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: European Union’s Horizon 2020 Research and Innovation Program under the ARTERY.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Minimally invasive mitral valve repair offers significant advantages over traditional open-heart surgery, yet it remains a complex procedure that exposes both patients and medical staff to radiation. To address these challenges, a significant research interest is growing in automating these manual procedures. Continuum robots represent a promising approach, thanks to their ability to navigate confined spaces. However, their nonlinear behavior presents challenges in modeling and control. In this study, we developed a robust position control method for a variable-length tendon-driven continuum robot. We designed a control system that effectively tracks the desired target positions by employing a constant curvature model and a Jacobian-based control algorithm with real-time position feedback. We assessed the stability of our system through Lyapunov analysis, demonstrating reliable convergence to these target positions. Experimental validation conducted in a cardiovascular phantom demonstrated significant improvements with respect to the state of the art. Our method achieved a trajectory following error of approximately 2.43 mm [1.63, 3.23] and a target position error of about 1.92 mm [1.73, 3.13]. Moreover, the computation time per trajectory point was reduced to approximately 0.04 seconds, highlighting enhanced computational efficiency. These results showcase improved accuracy and efficiency in minimally invasive mitral valve repair procedures.

Förderung

  • European Union’s Horizon 2020 Research and Innovation Program under the ARTERY

Zitieren

APA

Bicchi, A., Zhang, X., Jara, B. I. F., Cannizzaro, V., Peloso, A., & Momi, E. D. (2025). Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair. IEEE Transactions on Medical Robotics and Bionics, 7(2), 562-571. https://doi.org/10.1109/tmrb.2025.3550674

Vancouver

Bicchi A, Zhang X, Jara BIF, Cannizzaro V, Peloso A, Momi ED. Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair. IEEE Transactions on Medical Robotics and Bionics. 2025;7(2):562-571. doi:10.1109/tmrb.2025.3550674

BibTeX
@article{Bicchi2025,
  author = {Bicchi, Anna and Zhang, Xiu and Jara, Benjamín Ignacio Fortuño and Cannizzaro, Vanessa and Peloso, Angela and Momi, Elena De},
  title = {Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair},
  journal = {IEEE Transactions on Medical Robotics and Bionics},
  year = {2025},
  volume = {7},
  number = {2},
  pages = {562--571},
  doi = {10.1109/tmrb.2025.3550674}
}
Kostenlos starten →