Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair
IEEE Transactions on Medical Robotics and Bionics · 2025-05 · 7 (2) · 562-571
DOI: 10.1109/tmrb.2025.3550674 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Robotics and Bionics, 2025-05. Verfasst von Anna Bicchi und 5 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: European Union’s Horizon 2020 Research and Innovation Program under the ARTERY.
Abstract (Originalsprache)
Minimally invasive mitral valve repair offers significant advantages over traditional open-heart surgery, yet it remains a complex procedure that exposes both patients and medical staff to radiation. To address these challenges, a significant research interest is growing in automating these manual procedures. Continuum robots represent a promising approach, thanks to their ability to navigate confined spaces. However, their nonlinear behavior presents challenges in modeling and control. In this study, we developed a robust position control method for a variable-length tendon-driven continuum robot. We designed a control system that effectively tracks the desired target positions by employing a constant curvature model and a Jacobian-based control algorithm with real-time position feedback. We assessed the stability of our system through Lyapunov analysis, demonstrating reliable convergence to these target positions. Experimental validation conducted in a cardiovascular phantom demonstrated significant improvements with respect to the state of the art. Our method achieved a trajectory following error of approximately 2.43 mm [1.63, 3.23] and a target position error of about 1.92 mm [1.73, 3.13]. Moreover, the computation time per trajectory point was reduced to approximately 0.04 seconds, highlighting enhanced computational efficiency. These results showcase improved accuracy and efficiency in minimally invasive mitral valve repair procedures.
Förderung
- European Union’s Horizon 2020 Research and Innovation Program under the ARTERY
Zitieren
APA
Bicchi, A., Zhang, X., Jara, B. I. F., Cannizzaro, V., Peloso, A., & Momi, E. D. (2025). Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair. IEEE Transactions on Medical Robotics and Bionics, 7(2), 562-571. https://doi.org/10.1109/tmrb.2025.3550674
Vancouver
Bicchi A, Zhang X, Jara BIF, Cannizzaro V, Peloso A, Momi ED. Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair. IEEE Transactions on Medical Robotics and Bionics. 2025;7(2):562-571. doi:10.1109/tmrb.2025.3550674
BibTeX
@article{Bicchi2025,
author = {Bicchi, Anna and Zhang, Xiu and Jara, Benjamín Ignacio Fortuño and Cannizzaro, Vanessa and Peloso, Angela and Momi, Elena De},
title = {Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair},
journal = {IEEE Transactions on Medical Robotics and Bionics},
year = {2025},
volume = {7},
number = {2},
pages = {562--571},
doi = {10.1109/tmrb.2025.3550674}
}
EUVIMED