EUVIMEDEUVIMED entdecken
Crossref

Design, Modeling and Optimization of a Magnetic Resonance Conditional 3-RRR Spherical Parallel Robot for Neurosurgery

Yanding Qin, Yueyang Shi, Longxin Wang, Hongpeng Wang, Jianda Han

IEEE Transactions on Medical Robotics and Bionics · 2024-05 · 6 (2) · 556-566

DOI: 10.1109/tmrb.2024.3387114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Robotics and Bionics, 2024-05. Verfasst von Yanding Qin und 4 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Shenzhen Science and Technology Program, Sustainable Development Science and Technology Special Project of Shenzhen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In neurosurgery, magnetic resonance (MR) imaging is extensively utilized for preoperative diagnosis and postoperative evaluation due to its superior soft tissue contrast. However, the strong magnetic field poses a challenge to the real-time utilization of MR for intraoperative navigation. To facilitate neurosurgery in the MR environment, this paper develops a MR conditional robot featuring nonferrous materials and ultrasonic motor actuation. The robot consists of a 3-degree-of-freedom (3-DOF) translational module and a 3-DOF remote center of motion (RCM) module. The RCM module incorporates a 3-RRR spherical parallel mechanism. The mechanical design and kinematic modeling of the RCM module is completed. This paper further conducts the optimization for the RCM module. Additionally, a path-planning algorithm, focusing on the maximization of dexterity, is introduced, and the feasible workspace of the optimized RCM module is evaluated. A prototype is fabricated, and the orientation repeatability of the RCM module is measured to be 0.055±0.0016∘, and the absolute orientation error is 2.05±0.019∘. Needle insertion experiments are performed on an agarose phantom to evaluate the feasibility of the robot. The impact on signal-to-noise ratio in MRI images caused by the robot is less than 4%, indicating a highly promising applicability in MR conditional neurosurgery.

Förderung

  • National Key Research and Development Program of China
  • Shenzhen Science and Technology Program
  • Sustainable Development Science and Technology Special Project of Shenzhen
  • Natural Science Foundation of Tianjin

Zitieren

APA

Qin, Y., Shi, Y., Wang, L., Wang, H., & Han, J. (2024). Design, Modeling and Optimization of a Magnetic Resonance Conditional 3-RRR Spherical Parallel Robot for Neurosurgery. IEEE Transactions on Medical Robotics and Bionics, 6(2), 556-566. https://doi.org/10.1109/tmrb.2024.3387114

Vancouver

Qin Y, Shi Y, Wang L, Wang H, Han J. Design, Modeling and Optimization of a Magnetic Resonance Conditional 3-RRR Spherical Parallel Robot for Neurosurgery. IEEE Transactions on Medical Robotics and Bionics. 2024;6(2):556-566. doi:10.1109/tmrb.2024.3387114

BibTeX
@article{Qin2024,
  author = {Qin, Yanding and Shi, Yueyang and Wang, Longxin and Wang, Hongpeng and Han, Jianda},
  title = {Design, Modeling and Optimization of a Magnetic Resonance Conditional 3-RRR Spherical Parallel Robot for Neurosurgery},
  journal = {IEEE Transactions on Medical Robotics and Bionics},
  year = {2024},
  volume = {6},
  number = {2},
  pages = {556--566},
  doi = {10.1109/tmrb.2024.3387114}
}
Kostenlos starten →