Spatial-Jitter Model for Magnetoencephalography Sensor Arrays
IEEE Transactions on Medical Imaging · 2026-07 · 45 (7) · 3908-3921
DOI: 10.1109/tmi.2026.3687982 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2026-07. Verfasst von Joonas Iivanainen. Hauptthemen laut MEDLINE: Magnetoencephalography, Signal Processing, Computer-Assisted, Models, Neurological. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, National Institute of Neurological Disorders and Stroke of the National Institutes of Health, Jenny ja Antti Wihurin Rahasto.
Abstract (Originalsprache)
Sampling jitter, i.e., random deviations in the time instants when samples are taken, causes frequency-dependent noise that reduces signal-to-noise ratio (SNR). This paper generalizes the concept of jitter to magnetoencephalography (MEG) sensor arrays that spatially sample the quasistatic magnetic field due to brain activity. It is shown that spatial jitter, i.e., random deviations in MEG sensor positions, causes spatial-frequency-dependent noise in the vector spherical harmonics domain that reduces the attainable SNR and spatial resolution in MEG. Similarly, the paper also considers noise due to random sensor orientation errors ('orientation jitter') and errors due to field integration by the finite-sized sensors ('aperture error'). The analysis in this paper shows that on-scalp MEG measurements taken closer to the head are more resistant to spatial and orientation jitter at high spatial frequencies than off-scalp measurements taken further away. On the other hand, on-scalp measurements are affected more by aperture errors than off-scalp measurements. The paper also provides new insights to the effect of sensor noise on the spatial resolution of on- and off-scalp sensor arrays using a novel normalization of the vector spherical harmonics. The paper also simulates spatial-jitter phenomena with realistic sensor arrays based on optically pumped magnetometers and superconducting quantum interference device sensors. This realistic simulation shows that spatial jitter reduces SNR and affects how the measurements should be regularized in order to maximize SNR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NINDS NIH HHS
- National Institute of Neurological Disorders and Stroke of the National Institutes of Health
- Jenny ja Antti Wihurin Rahasto
- Instrumentariumin Tiedesäätiö
- Research Council of Finland
Zitieren
APA
Iivanainen, J. (2026). Spatial-Jitter Model for Magnetoencephalography Sensor Arrays. IEEE Transactions on Medical Imaging, 45(7), 3908-3921. https://doi.org/10.1109/tmi.2026.3687982
Vancouver
Iivanainen J. Spatial-Jitter Model for Magnetoencephalography Sensor Arrays. IEEE Transactions on Medical Imaging. 2026;45(7):3908-3921. doi:10.1109/tmi.2026.3687982
BibTeX
@article{Iivanainen2026,
author = {Iivanainen, Joonas},
title = {Spatial-Jitter Model for Magnetoencephalography Sensor Arrays},
journal = {IEEE Transactions on Medical Imaging},
year = {2026},
volume = {45},
number = {7},
pages = {3908--3921},
doi = {10.1109/tmi.2026.3687982}
}
EUVIMED