EUVIMEDEUVIMED entdecken
Open Access

Clinical Metadata-Guided Limited-Angle CT Image Reconstruction

Yu Shi, Shuyi Fan, Changsheng Fang, Shuo Han, Haodong Li, Li Zhou, Bahareh Morovati, Dayang Wang, Hengyong Yu

IEEE Transactions on Medical Imaging · 2026-07 · 45 (7) · 3490-3504

DOI: 10.1109/tmi.2026.3677586 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2026-07. Verfasst von Yu Shi und 8 weiteren Autor:innen. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Image Processing, Computer-Assisted, Metadata. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NCI NIH HHS, NIH/National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Limited-angle computed tomography (LACT) improves temporal resolution and reduces radiation dose, but suffers from severe artifacts due to missing projections. Clinical workflows record abundant patient- and acquisition-level metadata, yet such information remains underutilized in image reconstruction. To tackle the ill-posed LACT inverse problem, we propose a metadata-guided two-stage diffusion framework that leverages structured clinical contexts as semantic priors for robust reconstruction. In Stage-I, we learn a metadata-to-anatomy generative prior by conditioning a transformer-based diffusion model on clinical metadata (acquisition parameters, patient demographics, and diagnostic impressions), and sampling a coarse anatomical estimate from Gaussian noise. In Stage-II, a second conditional diffusion model performs coarse-to-fine refinement, using the Stage-I estimate as an image prior while re-injecting the same metadata to recover full-resolution anatomy. To preserve anatomical fidelity and suppress hallucinations, projection-domain data consistency is enforced periodically after denoising update via an ADMM-based solver. Experiments on the public multimodal CTRATE dataset demonstrate that the proposed framework outperforms iterative, CNN-based, and diffusion-based baselines, with the greatest gains under severe truncation, e.g., up to 5.23%/11.21% higher SSIM/PSNR than the strongest metadata-free diffusion competitor at 90°. On real clinical cardiac CT, it yields coronary artery calcium scores closer to full-view references, indicating improved clinical utility. Furthermore, the proposed method is generalized to out-of-distribution angular ranges and projection geometries, and ablation results confirm complementary contributions from different metadata types under limited-angle conditions. Our results highlight clinical metadata as actionable semantic priors to synergize with physics-informed constraints to improve both reconstruction fidelity and clinical quantification in LACT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedImage Processing, Computer-AssistedMetadataHumansAlgorithms

Förderung

  • NIBIB NIH HHS
  • NCI NIH HHS
  • NIH/National Institute of Biomedical Imaging and Bioengineering
  • NIH/National Cancer Institute

Zitieren

APA

Shi, Y., Fan, S., Fang, C., Han, S., Li, H., Zhou, L., Morovati, B., Wang, D., & Yu, H. (2026). Clinical Metadata-Guided Limited-Angle CT Image Reconstruction. IEEE Transactions on Medical Imaging, 45(7), 3490-3504. https://doi.org/10.1109/tmi.2026.3677586

Vancouver

Shi Y, Fan S, Fang C, Han S, Li H, Zhou L, et al. Clinical Metadata-Guided Limited-Angle CT Image Reconstruction. IEEE Transactions on Medical Imaging. 2026;45(7):3490-3504. doi:10.1109/tmi.2026.3677586

BibTeX
@article{Shi2026,
  author = {Shi, Yu and Fan, Shuyi and Fang, Changsheng and Han, Shuo and Li, Haodong and Zhou, Li and Morovati, Bahareh and Wang, Dayang and Yu, Hengyong},
  title = {Clinical Metadata-Guided Limited-Angle CT Image Reconstruction},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2026},
  volume = {45},
  number = {7},
  pages = {3490--3504},
  doi = {10.1109/tmi.2026.3677586}
}