Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-11. Verfasst von Tianqi Chen und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Imaging, Three-Dimensional. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIBIB NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Positron Emission Tomography (PET) is an important clinical imaging tool but inevitably introduces radiation exposure to patients and healthcare providers. Reducing the tracer injection dose and eliminating the CT acquisition for attenuation correction can reduce the overall radiation dose, but often results in PET with high noise and bias. Thus, it is desirable to develop 3D methods to translate the non-attenuation-corrected low-dose PET (NAC-LDPET) into attenuation-corrected standard-dose PET (AC-SDPET). Recently, diffusion models have emerged as a new state-of-the-art deep learning method for image-to-image translation, better than traditional CNN-based methods. However, due to the high computation cost and memory burden, it is largely limited to 2D applications. To address these challenges, we developed a novel 2.5D Multi-view Averaging Diffusion Model (MADM) for 3D image-to-image translation with application on NAC-LDPET to AC-SDPET translation. Specifically, MADM employs separate diffusion models for axial, coronal, and sagittal views, whose outputs are averaged in each sampling step to ensure the 3D generation quality from multiple views. To accelerate the 3D sampling process, we also proposed a strategy to use the CNN-based 3D generation as a prior for the diffusion model. Our experimental results on human patient studies suggested that MADM can generate high-quality 3D translation images, outperforming previous CNN-based and Diffusion-based baseline methods. The code is available at https://github.com/tianqic/MADM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographyImaging, Three-DimensionalHumansPhantoms, ImagingDeep LearningAlgorithmsTomography, X-Ray Computed

Förderung

  • NCI NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Chen, T., Hou, J., Zhou, Y., Xie, H., Chen, X., Liu, Q., Guo, X., Xia, M., Duncan, J. S., Liu, C., & Zhou, B. (2025). 2.5D Multi-View Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-Count PET Reconstruction With CT-Less Attenuation Correction. IEEE Transactions on Medical Imaging, 44(11), 4239-4250. https://doi.org/10.1109/tmi.2025.3570342

Vancouver

Chen T, Hou J, Zhou Y, Xie H, Chen X, Liu Q, et al. 2.5D Multi-View Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-Count PET Reconstruction With CT-Less Attenuation Correction. IEEE Transactions on Medical Imaging. 2025;44(11):4239-4250. doi:10.1109/tmi.2025.3570342

BibTeX
@article{Chen2025,
  author = {Chen, Tianqi and Hou, Jun and Zhou, Yinchi and Xie, Huidong and Chen, Xiongchao and Liu, Qiong and Guo, Xueqi and Xia, Menghua and Duncan, James S and Liu, Chi and Zhou, Bo},
  title = {2.5D Multi-View Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-Count PET Reconstruction With CT-Less Attenuation Correction},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2025},
  volume = {44},
  number = {11},
  pages = {4239--4250},
  doi = {10.1109/tmi.2025.3570342}
}
Kostenlos starten →