STARTS: A Self-Adapted Spatio-Temporal Framework for Automatic E/MEG Source Imaging
IEEE Transactions on Medical Imaging · 2025
DOI: 10.1109/tmi.2024.3483292 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025. Verfasst von Zhao Feng und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Magnetoencephalography, Signal Processing, Computer-Assisted, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Zhejiang Provincial NSFC, National Key Research and Development Program of China.
Abstract (Originalsprache)
To obtain accurate brain source activities, the highly ill-posed source imaging of electro- and magneto-encephalography (E/MEG) requires proficiency in incorporation of biophysiological constraints and signal-processing techniques. Here, we propose a spatio-temporal-constrainted E/MEG source imaging framework-STARTS that can reconstruct the source in a fully automatic way. Specifically, a block-diagonal covariance was adopted to reconstruct the source extents while maintain spatial homogeneity. Temporal basis functions (TBFs) of both sources and noise were estimated and updated in a data-driven fashion to alleviate the influence of noises and further improve source localization accuracy. The performance of the proposed STARTS was quantitatively assessed through a series of simulation experiments, wherein superior results were obtained in comparison with the benchmark ESI algorithms (including LORETA, EBI-Convex, BESTIES & SI-STBF). Additional validations on epileptic and resting-state EEG data further indicate that the STARTS can produce neurophysiologically plausible results. Moreover, a computationally efficient version of STARTS: smooth STARTS was also introduced with an elementary spatial constraint, which exhibited comparable performance and reduced execution cost. In sum, the proposed STARTS, with its advanced spatio-temporal constraints and self-adapted update operation, provides an effective and efficient approach for E/MEG source imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- National Natural Science Foundation of China
- Zhejiang Provincial NSFC
- National Key Research and Development Program of China
- Key Research and Development Programof Zhejiang Province
Zitieren
APA
Feng, Z., Guan, C., Zheng, R., & Sun, Y. (2025). STARTS: A Self-Adapted Spatio-Temporal Framework for Automatic E/MEG Source Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2024.3483292
Vancouver
Feng Z, Guan C, Zheng R, Sun Y. STARTS: A Self-Adapted Spatio-Temporal Framework for Automatic E/MEG Source Imaging. IEEE Transactions on Medical Imaging. 2025. doi:10.1109/tmi.2024.3483292
BibTeX
@article{Feng2025,
author = {Feng, Zhao and Guan, Cuntai and Zheng, Ruifeng and Sun, Yu},
title = {STARTS: A Self-Adapted Spatio-Temporal Framework for Automatic E/MEG Source Imaging},
journal = {IEEE Transactions on Medical Imaging},
year = {2025},
doi = {10.1109/tmi.2024.3483292}
}
EUVIMED