EUVIMEDEUVIMED entdecken
Crossref

PST-Diff: Achieving High-Consistency Stain Transfer by Diffusion Models With Pathological and Structural Constraints

Yufang He, Zeyu Liu, Mingxin Qi, Shengwei Ding, Peng Zhang, Fan Song, Chenbin Ma, Huijie Wu, Ruxin Cai, Youdan Feng, Haonan Zhang, Tianyi Zhang und 1 weitere

IEEE Transactions on Medical Imaging · 2024-10 · 43 (10) · 3634-3647

DOI: 10.1109/tmi.2024.3430825 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024-10. Verfasst von Yufang He und 12 weiteren Autor:innen. Hauptthemen laut MEDLINE: Algorithms. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation, Fundamental Research Funds for Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Histopathological examinations heavily rely on hematoxylin and eosin (HE) and immunohistochemistry (IHC) staining. IHC staining can offer more accurate diagnostic details but it brings significant financial and time costs. Furthermore, either re-staining HE-stained slides or using adjacent slides for IHC may compromise the accuracy of pathological diagnosis due to information loss. To address these challenges, we develop PST-Diff, a method for generating virtual IHC images from HE images based on diffusion models, which allows pathologists to simultaneously view multiple staining results from the same tissue slide. To maintain the pathological consistency of the stain transfer, we propose the asymmetric attention mechanism (AAM) and latent transfer (LT) module in PST-Diff. Specifically, the AAM can retain more local pathological information of the source domain images, while ensuring the model's flexibility in generating virtual stained images that highly confirm to the target domain. Subsequently, the LT module transfers the implicit representations across different domains, effectively alleviating the bias introduced by direct connection and further enhancing the pathological consistency of PST-Diff. Furthermore, to maintain the structural consistency of the stain transfer, the conditional frequency guidance (CFG) module is proposed to precisely control image generation and preserve structural details according to the frequency recovery process. To conclude, the pathological and structural consistency constraints provide PST-Diff with effectiveness and superior generalization in generating stable and functionally pathological IHC images with the best evaluation score. In general, PST-Diff offers prospective application in clinical virtual staining and pathological image analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsHumansImmunohistochemistryImage Processing, Computer-AssistedStaining and LabelingEosine Yellowish-(YS)

Substanzen

Eosine Yellowish-(YS)

Förderung

  • National Natural Science Foundation of China
  • Beijing Natural Science Foundation
  • Fundamental Research Funds for Central Universities

Zitieren

APA

He, Y., Liu, Z., Qi, M., Ding, S., Zhang, P., Song, F., Ma, C., Wu, H., Cai, R., Feng, Y., Zhang, H., Zhang, T., & Zhang, G. (2024). PST-Diff: Achieving High-Consistency Stain Transfer by Diffusion Models With Pathological and Structural Constraints. IEEE Transactions on Medical Imaging, 43(10), 3634-3647. https://doi.org/10.1109/tmi.2024.3430825

Vancouver

He Y, Liu Z, Qi M, Ding S, Zhang P, Song F, et al. PST-Diff: Achieving High-Consistency Stain Transfer by Diffusion Models With Pathological and Structural Constraints. IEEE Transactions on Medical Imaging. 2024;43(10):3634-3647. doi:10.1109/tmi.2024.3430825

BibTeX
@article{He2024,
  author = {He, Yufang and Liu, Zeyu and Qi, Mingxin and Ding, Shengwei and Zhang, Peng and Song, Fan and Ma, Chenbin and Wu, Huijie and Cai, Ruxin and Feng, Youdan and Zhang, Haonan and Zhang, Tianyi and Zhang, Guanglei},
  title = {PST-Diff: Achieving High-Consistency Stain Transfer by Diffusion Models With Pathological and Structural Constraints},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2024},
  volume = {43},
  number = {10},
  pages = {3634--3647},
  doi = {10.1109/tmi.2024.3430825}
}