EUVIMEDEUVIMED entdecken
Crossref

Concept-Based Lesion Aware Transformer for Interpretable Retinal Disease Diagnosis

Chi Wen, Mang Ye, He Li, Ting Chen, Xuan Xiao

IEEE Transactions on Medical Imaging · 2025-01 · 44 (1) · 57-68

DOI: 10.1109/tmi.2024.3429148 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-01. Verfasst von Chi Wen und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Retinal Diseases, Retina, Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Research and Development Project of Hubei Province, Interdisciplinary Innovative Talents Foundation from Renmin Hospital of Wuhan University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Existing deep learning methods have achieved remarkable results in diagnosing retinal diseases, showcasing the potential of advanced AI in ophthalmology. However, the black-box nature of these methods obscures the decision-making process, compromising their trustworthiness and acceptability. Inspired by the concept-based approaches and recognizing the intrinsic correlation between retinal lesions and diseases, we regard retinal lesions as concepts and propose an inherently interpretable framework designed to enhance both the performance and explainability of diagnostic models. Leveraging the transformer architecture, known for its proficiency in capturing long-range dependencies, our model can effectively identify lesion features. By integrating with image-level annotations, it achieves the alignment of lesion concepts with human cognition under the guidance of a retinal foundation model. Furthermore, to attain interpretability without losing lesion-specific information, our method employs a classifier built on a cross-attention mechanism for disease diagnosis and explanation, where explanations are grounded in the contributions of human-understandable lesion concepts and their visual localization. Notably, due to the structure and inherent interpretability of our model, clinicians can implement concept-level interventions to correct the diagnostic errors by simply adjusting erroneous lesion predictions. Experiments conducted on four fundus image datasets demonstrate that our method achieves favorable performance against state-of-the-art methods while providing faithful explanations and enabling concept-level interventions. Our code is publicly available at https://github.com/Sorades/CLAT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Retinal DiseasesRetinaImage Interpretation, Computer-AssistedDeep LearningDiagnosis, Computer-AssistedOphthalmologyHumansFundus OculiNeural Networks, ComputerDatasets as TopicComputer Simulation

Förderung

  • National Natural Science Foundation of China
  • Key Research and Development Project of Hubei Province
  • Interdisciplinary Innovative Talents Foundation from Renmin Hospital of Wuhan University

Zitieren

APA

Wen, C., Ye, M., Li, H., Chen, T., & Xiao, X. (2025). Concept-Based Lesion Aware Transformer for Interpretable Retinal Disease Diagnosis. IEEE Transactions on Medical Imaging, 44(1), 57-68. https://doi.org/10.1109/tmi.2024.3429148

Vancouver

Wen C, Ye M, Li H, Chen T, Xiao X. Concept-Based Lesion Aware Transformer for Interpretable Retinal Disease Diagnosis. IEEE Transactions on Medical Imaging. 2025;44(1):57-68. doi:10.1109/tmi.2024.3429148

BibTeX
@article{Wen2025,
  author = {Wen, Chi and Ye, Mang and Li, He and Chen, Ting and Xiao, Xuan},
  title = {Concept-Based Lesion Aware Transformer for Interpretable Retinal Disease Diagnosis},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2025},
  volume = {44},
  number = {1},
  pages = {57--68},
  doi = {10.1109/tmi.2024.3429148}
}
Kostenlos starten →